Recommendations for Defining and Reporting Adherence Measured by Biometric Monitoring Technologies: Systematic Review
Notice bibliographique
Résumé
BACKGROUND: Suboptimal adherence to data collection procedures or a study intervention is often the cause of a failed clinical trial. Data from connected sensors, including wearables, referred to here as biometric monitoring technologies (BioMeTs), are capable of capturing adherence to both digital therapeutics and digital data collection procedures, thereby providing the opportunity to identify the determinants of adherence and thereafter, methods to maximize adherence. OBJECTIVE: We aim to describe the methods and definitions by which adherence has been captured and reported using BioMeTs in recent years. Identifying key gaps allowed us to make recommendations regarding minimum reporting requirements and consistency of definitions for BioMeT-based adherence data. METHODS: We conducted a systematic review of studies published between 2014 and 2019, which deployed a BioMeT outside the clinical or laboratory setting for which a quantitative, nonsurrogate, sensor-based measurement of adherence was reported. After systematically screening the manuscripts for eligibility, we extracted details regarding study design, participants, the BioMeT or BioMeTs used, and the definition and units of adherence. The primary definitions of adherence were categorized as a continuous variable based on duration (highest resolution), a continuous variable based on the number of measurements completed, or a categorical variable (lowest resolution). RESULTS: Our PubMed search terms identified 940 manuscripts; 100 (10.6%) met our eligibility criteria and contained descriptions of 110 BioMeTs. During literature screening, we found that 30% (53/177) of the studies that used a BioMeT outside of the clinical or laboratory setting failed to report a sensor-based, nonsurrogate, quantitative measurement of adherence. We identified 37 unique definitions of adherence reported for the 110 BioMeTs and observed that uniformity of adherence definitions was associated with the resolution of the data reported. When adherence was reported as a continuous time-based variable, the same definition of adherence was adopted for 92% (46/50) of the tools. However, when adherence data were simplified to a categorical variable, we observed 25 unique definitions of adherence reported for 37 tools. CONCLUSIONS: We recommend that quantitative, nonsurrogate, sensor-based adherence data be reported for all BioMeTs when feasible; a clear description of the sensor or sensors used to capture adherence data, the algorithm or algorithms that convert sample-level measurements to a metric of adherence, and the analytic validation data demonstrating that BioMeT-generated adherence is an accurate and reliable measurement of actual use be provided when available; and primary adherence data be reported as a continuous variable followed by categorical definitions if needed, and that the categories adopted are supported by clinical validation data and/or consistent with previous reports.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,031 | 0,159 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,003 | 0,000 |
| Bibliométrie | 0,001 | 0,002 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,003 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; les deux têtes enseignantes s’accordent sur ce qui est montré ici.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».