The Added Value of Patch Testing Beyond the Baseline Tray
Notice bibliographique
Résumé
BACKGROUND: The patch test is the standard for diagnosing allergic contact dermatitis. Standardized trays allow the examination of the most prevalent allergens, whereas customized trays are more appropriate for addressing specific allergens and require expertise. They are therefore usually performed in specialized clinics. METHODS: We assessed the results of 4355 patch tests performed between 2012 and 2020 in a contact dermatitis clinic located in a large tertiary medical center. All patients were tested using the European baseline series and additional trays as clinically indicated. We assessed the frequency of relevant positive reactions outside the European baseline series. We then examined the added value and number of tests (NNTs) that need to be performed to elicit one relevant positive reaction per tray and common allergens. RESULTS: Nine hundred fifty-four patients (21.9%) had 1 or more positive relevant reactions; 43.3% tested positive for an allergen outside the European baseline series (OEBS). The acrylate and fragrance trays were highly represented among the positive and relevant reactions OEBS with NNTs of 4.4 and 6.8, respectively. 2-Hydroxyethyl methacrylate is the most prevalent allergen OEBS and is considered a marker for acrylate sensitivity with a high rate of cross-reactions and concordance rate of 85%, justifying its addition to the EBS in 2018. Other highly represented allergens include chloramphenicol, 2-hydroxyethyl acrylate, and Amerchol L-101, a lanolin derivative. The cosmetics and textile trays, although often tested, have relatively low added values of 3.7% and 2.3%, respectively. Surprisingly, the cutaneous adverse drug reaction series tray (CAD-1000) yielded no positive reactions, whereas testing the patients' medication yielded positive results in 10.9% of the cases. CONCLUSIONS: Expanded patch testing is crucial to accurately diagnose allergic contact dermatitis and almost doubles the number of patients with relevant positive reactions. Acrylate sensitivity is an emerging epidemic with a high positive reaction rate and low NNT, as is sensitivity to the allergens in the fragrance tray. 2-Hydroxyethyl methacrylate is a reliable marker for acrylate sensitivity with a concordance rate of 85%. Chloramphenicol is a common culprit and should be added to the standard tray in countries with a high usage rate. A low NNT was also observed when testing the patients' own cosmetics and medications; this should, therefore, be encouraged. The textile tray yielded a relatively high NNT; however, it should be performed when clinically indicated in the absence of a reliable marker in the EBS.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,006 | 0,031 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,001 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,005 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».