Combined Dual-Prediction Based Data Fusion and Enhanced Leak Detection and Isolation Method for WSN Pipeline Monitoring System
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
In a Wireless Sensor Networks (WSN) based fluid pipeline leak monitoring system, numerous sensors are deployed along the pipeline networks. A great amount of measurements are continuously transmitted from the sensor nodes to their corresponding sink nodes. The energy consumed on data transmission dominates the power depletion of a WSN system. To reduce the amount of data transmission and prolong the lifetime of WSN, in this paper, a Combined Dual-Prediction based Data Fusion (CDPDF) method is proposed. Transmissions are only triggered if the measurement is substantially different from the predicted value. Furthermore, unlike existing methods which establish the predictor by merely considering the measurements from a single sensor, the proposed CDPDF learns and updates the predictor by integrating measurements from multiple neighboring sensors, hence the spatial cross-correlation is taken into account and the prediction accuracy is significantly improved. In this paper, an Enhanced Leak Detection and Isolation (EnLDI) method is also proposed in which several important parameters, such as the friction factor and the pressure wave propagation speed, can be online updated, resulting in improvement of the leak localization accuracy. Experimental case studies are conducted. By employing the proposed CDPDF and EnLDI methods in pipeline networks monitoring, the accuracy of leak isolation is significantly increased with reduced data transmission demands. Note to Practitioners—This work delivers a hybrid scheme that combines machine learning based data fusion and transmission, with model-based leak detection and isolation. The work is motivated by the problem of high energy consumption on data transmission and poor leak diagnosis accuracy in WSN based pipeline networks monitoring system. To reduce the energy consumed during frequent transmissions among sensor nodes, in this paper, a machine learning based data fusion method is proposed which can eliminate most of the redundant transmissions. Among the investigated schemes, the Extreme Learning Machine (ELM) based predictor can not only achieve satisfactory prediction accuracy but also has low computational cost, hence it can be easily implemented in most of the embedded micro-controller systems in practice. At the base station of a WSN, in the leak diagnosis phase, traditional model-based methods employ the fixed model parameters which should be adjustable in different pressure and flow conditions etc. In this paper, an online model parameter estimation procedure is introduced and incorporated in the scheme designed to estimate the leak size and location, thus, the leak localization accuracy is significantly improved. Moreover, the algorithmic procedures, mathematical expressions, evaluation process and results are also provided for practical implementation.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,001 | 0,000 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle