Enhanced Reactive Power Sharing and Voltage Restoration Based on Adaptive Virtual Impedance and Consensus Algorithm
Notice bibliographique
Résumé
In this paper, power-sharing management control on an AC islanded microgrid is investigated to achieve accurate reactive power sharing. The droop control method is primarily used to manage the active and reactive power sharing among the DGs in the microgrid. However, the line impedance mismatch causes unbalanced reactive power sharing. As a solution a consensus-based adaptive virtual impedance controller is proposed, where the consensus algorithm is used to set the reactive power mismatch; then a virtual impedance correction term is generated through a proportional-integral controller to eliminate the line impedance mismatch. Thus, reactive power sharing is achieved without knowledge of the line impedances or using a central controller. Moreover, the consensus algorithm is used to restore the AC bus voltage to the nominal value by estimating the DGs average voltage using neighbor communication to compensate for the decreased magnitude of the voltage reference. Matlab/Simulink is used to validate the accuracy of reactive power sharing and voltage restauration achievement of the proposed solution through simulation of different scenarios. In addition, a dSPACE DS1104 is used within a developed experimental testbench based on two parallel DGs to validate the effectiveness of the proposed solution in the real world.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».