MétaCan
Menu
Retour à la cohorte
Enregistrement W4236333371 · doi:10.1002/9780470027318.a6015

Quadrupole Ion Trap Mass Spectrometer

2000· other· en· W4236333371 sur OpenAlex
Raymond E. March

Pourquoi ce travail est dans la base

Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.

affAu moins un auteur déclare une institution canadienne dans l'instantané OpenAlex épinglé.

Notice bibliographique

RevueEncyclopedia of Analytical Chemistry · 2000
Typeother
Langueen
DomaineChemistry
ThématiqueMass Spectrometry Techniques and Applications
Établissements canadiensTrent University
Organismes subventionnairesnon disponible
Mots-clésMass spectrometryIonQuadrupole ion trapIon trapQuadrupole mass analyzerHybrid mass spectrometerChemistryTriple quadrupole mass spectrometerIon trappingAtomic physicsQuadrupoleSpectrometerMass spectrumSecondary ion mass spectrometryAnalytical Chemistry (journal)ElectrodeTandem mass spectrometryPhysicsSelected reaction monitoringOptics

Résumé

récupéré en direct d'OpenAlex

Abstract The quadrupole ion trap is constructed of three electrodes that, when held at appropriate potentials, cause the formation of a trapping pseudo‐potential well so that charged particles, or gaseous ions, may be confined or stored for long periods of time. The two end‐cap electrodes resemble saucers while the ring electrode resembles a napkin ring; all of the electrodes are of hyperbolic geometry. The ion trap itself functions as a mass spectrometer when the ion‐confining conditions are modified such that ions are ejected mass‐selectively from the trapping potential well. As ions of successive mass/charge ratios are ejected in turn from the ion trap, they impinge upon an external detector whereby ion signals are created in proportion to the ion number of each species; in this manner, a mass spectrum is generated. The QITMS (quadrupole ion trap mass spectrometer) is an extraordinary instrument in that it is physically small (the entire electrode assembly can be held in the palm of one's hand) compared with magnetic and electric sector instruments, it is relatively inexpensive, it is one of the most, if not the most, sensitive mass spectrometers and, since several mass‐selective operations can be carried in succession, the ion trap can function as a tandem mass spectrometer. Tandem mass spectrometric operation is described as (MS) n . With the QITMS, (MS) n is carried out in time in the same volume of space whereas (MS) n in sector instruments is carried out in space. With sector instruments, the maximum value of n is n = 4 yet with the ion trap, (MS) n where n = 4–6 can be carried out routinely and n = 13 has been achieved. The QITMS shares several similarities with the ion cyclotron resonance mass spectrometer yet the cost of the former is about one‐tenth that of the latter. One striking difference between the QITMS and all other mass spectrometers is that the QITMS operates at a pressure of 10 −3 Torr compared with 10 −6 –10 −9 Torr for other mass spectrometers. The theory of ion confinement and ion trajectory manipulation in the QITMS has been explained relatively simply so far. Since the theory differs widely from those of sector instruments and ion cyclotron resonance mass spectrometry (ICR/MS), it will not be familiar to those who have not had the opportunity to examine ion motion in quadrupole fields. Optimum operation of the QITMS is effected by collisional focusing of the ion cloud to the center of the ion trap under the influence of helium buffer gas. Since the movement of ions confined in the ion trap is periodic, the trajectories of collisionally focused ions can be expanded by resonance excitation effected by the imposition of supplementary radio frequency (rf) potentials of low amplitude to the end‐cap electrodes of the ion trap. This excitation operation permits isolation of selected ion species, by ejection of unwanted ion species, followed by selective ion/molecule reaction or by collision‐induced dissociation (CID) with subsequent mass analysis of the product/fragment ions formed. Sample calculations are given of all of the relevant trapping parameters. Applications of the QITMS as a single stage mass spectrometer and as a tandem mass spectrometer are discussed. The operation of the QITMS for the identication of Dioxins and furans co‐eluting from a gas chromatograph is described. In addition, the application of chemical ionization (CI) for the identification of co‐eluting polychlorinated biphenyl (PCB) congeners is discussed. The QITMS is an extraordinary instrument that is capable of great sensitivity, high mass range and high mass resolution. Since the QITMS is compatible with methods for generating ions externally, such as electrospray ionization (ESI), its continued growth in many areas of mass spectrometry (MS) is assured.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMéta-épidémiologie (sens strict), Charge utile insuffisante (le modèle a refusé de juger)
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Sans objet · Signal consensuel: Sans objet
GenreSignal candidat: Autre · Signal consensuel: Autre
Score de désaccord entre enseignants0,362
Score d'incertitude au seuil1,000

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0010,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0010,000
Intégrité de la recherche0,0010,001
Charge utile insuffisante (le modèle a refusé de juger)0,3620,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,007
Tête enseignante GPT0,248
Écart entre enseignants0,240 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle