Study of Sulfur-Based Electrodes By Operando Acoustic Emission
Notice bibliographique
Résumé
The acoustic emission (AE) technique has been widely used since the 70’s for detecting anomalies such as leakages and cracks on large structure (e.g. bridges, pressure containers, and pipe lines). The analysis of the AE signals (transient elastic waves) can also be used to characterize the degradation mechanisms (crack growth, friction, delamination, matrix cracking, corrosion, etc) of various materials subjected to a stress by mechanical, pressure or thermal means. Recently, AE technique has also been used to evaluate the degradation of metal hydride electrodes for Ni-MH [1] and Si-based electrodes for Li-ion batteries [2,3]. Cracking of the active material and gas evolution are the main sources of AE signals identified in these studies. In the present study, the AE technique is used for studying upon cycling the mechanical degradation of S-based electrodes for Li/S batteries. The AE signals were recorded by a piezoelectric transducer fixed on the back of the working electrode. S-based electrodes made with two different binders (PVdF vs. CMC) and two different current collectors (standard Al foil vs. porous 3D carbon paper) were studied. In all cases, AE signals were mainly detected during the first plateau of the first discharge, suggesting that the electrode degradation mostly occurs during the initial dissolution of the S8 particles. AE signals were also detected during a few subsequent cycles when CMC binder is used. This is attributed to a better propagation of the AE signals through the electrode thanks to an improved adhesion of the electrode to the current collector in comparison to PVdF binder. This is confirmed by further mechanical resistance testing (peel and scratch tests). The use of a carbon paper as a current collector combined to CMC binder greatly improves the electrochemical performance of the S electrode by preventing the collapse of the electrode upon cycling. This electrode also presents an increased amount of AE signals, suggesting that the carbon fibres of the C paper act as an AE waveguide. This study demonstrated that AE could be used as an efficient tool to monitor the morphological degradation of S-based electrodes upon their cycling and offers relevant information for optimizing their formulation and architecture. A. Etiemble, H. Idrissi, P. Bernard, L. Roué. New insights into the pulverization of LaNi 5 -based alloys with different Co contents from electrochemical acoustic emission measurements. Electrochim. Acta 186 (2015) 112-116 A. Tranchot, A. Etiemble, P-X. Thivel, H. Idrissi., L. Roué. In-situ acoustic emission study of Si-based electrodes for Li-ion batteries, J. Power Sources 279 (2015) 259-266. A. Tranchot, P-X. Thivel, H. Idrissi, L. Roué. Influence of the Si particle size on the mechanical stability of Si-based electrodes evaluated by in-operando dilatometry and acoustic emission . J. Power Sources 330 (2016) 253-260. Figure 1
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».