Effect of Channel Length on the Gas-Liquid Two-Phase Flow Phenomena in a Microchannel
Notice bibliographique
Résumé
An optical measurement system was used to investigate the effect of microchannel length on adiabatic gas-liquid two-phase flow characteristics. Experiments were conducted with 146 mm and 1,571 mm long, circular microchannels of 100 micron diameter. Two-phase flow patterns, void fraction, gas and liquid plug lengths and their velocities were measured for two inlet configurations and gas-liquid mixing, i.e., (a) reducer and (b) T-junction. The test section length was found to have a significant effect on the two-phase flow characteristics measured at the same axial location in the microchannel test section typified by the void fraction data. The mean void fraction data obtained in the shorter (146 mm) microchannel with the reducer inlet agreed well with the equation by Kawahara and Kawaji which was previously proposed. On the other hand, the mean void fraction obtained at 36 mm from the inlet in the longer (1,571 mm) microchannel corresponded well with the homogeneous flow model and Armand’s equation for both reducer and T-junction inlet configurations. In the present experimental ranges of superficial gas velocity, jG = 0.03 ∼ 14 m/s, and superficial liquid velocity, jL = 0.04∼0.7 m/s, the gas and liquid plugs obtained in the longer microchannel had relatively shorter lengths and higher velocities than those in the shorter channel. Thus, both the microchannel length and inlet geometry were found to affect the two-phase flow characteristics in a microchannel.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,001 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».