An experimental study of soil thermal conductivity using a guarded hot plate apparatus
Notice bibliographique
Résumé
A guarded hot plate apparatus was used to generate comprehensive sets of thermal conductivity for two types of soils, namely Ottawa sand and Richmon Hill clay-loam, for temperature variation from 2 to 92°C and moisture content variation from complete dryness to full saturation with measurement errors of less than 3%. Numerical simulation of heat transfer within the apparatus with sample inside was performed to validate the experimental design and setup. To prepare the samples, a consistent specimen preparation technique was developed for the cases of dry, barely-to-moderately moist, and highly-to-fully saturated moist soils. On the basis of gathered datasets, empirical correlations for soil thermal conductivity were developed as a function of both temperature and moisture content. The proposed correlations produced excellent fit to majority of the experimental data, and could be easily integrated into numerical analysis of underground heat transfer. As an application example, one of the correlations was employed to evaluate soil thermal conductivity in a numerical study of underground heat loss from a basement wall and floor, in order to illustrate the importance of considering the dependence of soil thermal conductivity on soil texture, temperature and degree of saturation.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».