Performance Evaluation of Small-Scale Solar Powered Wastewater and Grey Water Treatment Systems
Notice bibliographique
Résumé
Onsite wastewater treatment systems are the most economical way of dealing with used water in an isolated environment. And because of the variability normally associated with the operation of these systems is linked to either varying hydraulic loading or the nature of the environment in which the system was installed, the performance of these systems needs to be evaluated to find out the optimum operating condition. In this work, the performance of two small-scale treatment systems used for wastewater and gray water was evaluated. This was done by comparing the measure of some physical, chemical and biological parameters in the effluent to the standards of effluent discharge sets by Dubai Municipality. The performance was also measured from other angles using the proposed Swedish Water and Wastewater Association performance indicators so as to give the analysis a wider coverage of economic and energy consumption. The result shows that the performance of the installed solar-powered treatment systems was enough to meet the requirements set by Dubai municipality for effluent discharge except for Ammonia-Nitrogen. Also, the deployment of solar power energy supply, coupled with a low energy usage of the two systems, has made this particular setting an environmentally sustainable setting for such an isolated site.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,001 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,001 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».