40Ar/39Ar step heat analyses of core from the N. Kalikpik Test Well #1
Notice bibliographique
Résumé
GMC Data Report #426 (2 of 7) Summary of the AnalysisFor 40 Ar/ 39 Ar analysis, two "tephra" samples was submitted to the Geochronology laboratory at UAF where it was crushed, sieved, washed and hand-picked for "glass" mineral phases.The monitor mineral MMhb-1 (Samson and Alexander, 1987) with an age of 523.5 Ma (Renne et al., 1994) was used to monitor neutron flux (and calculate the irradiation parameter, J).The samples and standards were wrapped in aluminum foil and loaded into aluminum cans of 2.5 cm diameter and 6 cm height.The samples were irradiated in position 8b of the uranium enriched research reactor of McMaster University in Hamilton, Ontario, Canada for 150 megawatt-hours.Upon their return from the reactor, the sample and monitors were loaded into 2 mm diameter holes in a copper tray that was then loaded in a ultra-high vacuum extraction line.The monitors were fused, and samples heated, using a 6-watt argon-ion laser following the technique described in York et al. (1981( ), Layer et al. (1987) ) and Layer (2000).Argon purification was achieved using a liquid nitrogen cold trap and a SAES Zr-Al getter at 400C.The samples were analyzed in a VG-3600 mass spectrometer at the Geophysical Institute, University of Alaska Fairbanks.The argon isotopes measured were corrected for system blank and mass discrimination, as well as calcium, potassium and chlorine interference reactions following procedures outlined in McDougall and Harrison (1999).Typical full-system 8 min laser blank values (in moles) were generally 2 × 10 -16 mol 40Ar, 3 × 10218 mol 39Ar, 9 × 10 -18 mol 38Ar and 2 × 10 -18 mol 36Ar, which are 10-50 times smaller than the sample/standard volume fractions.Correction factors for nucleogenic interferences during irradiation were determined from irradiated CaF2 and K2SO4 as follows: (39Ar/37Ar)Ca = 7.06 × 10 -4 , (36Ar/37Ar)Ca = 2.79 × 10 -4 and (40Ar/39Ar)K = 0.0297.Mass discrimination was monitored by running calibrated air shots.The mass discrimination during these experiments was 0.8% per mass unit.While doing our experiments, calibration measurements were made on a weekly-monthly basis to check for changes in mass discrimination with no significant variation seen during these intervals.A summary of all the 40 Ar/ 39 Ar results is given in Table 1, with all ages quoted to the ± 1 sigma level and calculated using the constants of Renne et al. (2010).The integrated age is the age given by the total gas measured and is equivalent to a potassium-argon (K-Ar) age.The spectrum provides a plateau age if three or more consecutive gas fractions represent at least 50% of the total gas release and are within two standard deviations of each other (Mean Square Weighted Deviation less than 2.5).
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,001 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,006 | 0,002 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».