Immuno-multiple reaction monitoring (iMRM) for quantitation of PD-L1 and PD-1-signaling proteins in non-small cell lung carcinoma (NSCLC).
Notice bibliographique
Résumé
2627 Background: More accurate predictive biomarkers of response to checkpoint inhibitors (CPIs) still is a major unmet need in oncology. PD-L1 immunohistochemistry (IHC) limitations include its analytical variability and the post-translational modifications of PD-1 signaling-associated proteins like glycosylation. Moreover, PD-L1 IHC is an imperfect surrogate of the tumor immune microenvironment, and immunoscoring is important but difficult to assess in a clinical setting. Proteomic based technologies can overcome these challenges, but the low concentration of these proteins and the presence of high background noise in formalin-fixed paraffin embedded (FFPE) tumors were limiting obstacles. In this study, we evaluate the benefit of a new approach we used with anti-peptide antibodies to purify surrogate peptides, while liquid chromatography (LC) was coupled to multiple reaction monitoring mass spectrometry (iMRM) to improve specificity and precision of protein quantitation. Methods: To determine the concentration of PD-L1, PD-1, PD-L2, NT5E, LCK and ZAP70, we used unique and well detectable proteolytic peptides as surrogates. In a refined protocol, we optimized protein extraction and digestion, peptide immuno-enrichment, LC and MRM parameters to maximize recovery, increase target-specific signal and reduce noise. Plus, we assessed the glycosylation status of PD-L1, PD-L2, and PD-1. The entire workflow was fully validated using 31 NSCLC FFPE tumors. PD-L1 quantitation by iMRM was compared to PD-L1 IHC clone 22C3. Results: On average, 71±29 µg (n = 52) of protein could be extracted from each 1–3 mm 3 NSCLC tumor FFPE core. The optimized iMRM method allowed the quantitation of PD-L1 and PD-1 down to 21 amol on-column. Inter- and intra-day repeatability were well below FDA guidelines (coefficients of variation [CV] < 20%) with average CVs of 5.2±4.0% (intra-day) and 4.5±2.6% (inter-day). Sample storage had no significant effect on peptide quantitation. The final multiplexed iMRM assay enables quantitation all targets and glycosylation states for > 40 samples in only 3 days (including external calibration and quality controls) and was used to quantify the PD-1/PD-L1 axis proteins successfully in all 31 NSCLC FFPE tumors. PD-L1 expression ranged from 2 amol/μg to 61 amol/μg of total protein. As expected, iMRM results correlated moderately (R = 0.56, ρ < 0.001) with PD-L1 IHC. PD-L1 glycosylation status ranged from 99.9±0.2%, and therefore did not explain the discrepancies between IHC and iMRM for these samples. Conclusions: Herein a robust iMRM workflow was developed for the quantitation of the PD-1/PD-L1 axis in FFPE. This proof-of-concept supports that MS-based assay can provide otherwise unavailable data (e.g., PD-L1 concentration, glycosylation status). CPI treated patient tumors are being currently processed to validate the predictive value of the assay.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,003 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».