Technology-Based Compensation Assessment and Detection of Upper Extremity Activities of Stroke Survivors: Systematic Review
Notice bibliographique
Résumé
BACKGROUND: Upper extremity (UE) impairment affects up to 80% of stroke survivors and accounts for most of the rehabilitation after discharge from the hospital release. Compensation, commonly used by stroke survivors during UE rehabilitation, is applied to adapt to the loss of motor function and may impede the rehabilitation process in the long term and lead to new orthopedic problems. Intensive monitoring of compensatory movements is critical for improving the functional outcomes during rehabilitation. OBJECTIVE: This review analyzes how technology-based methods have been applied to assess and detect compensation during stroke UE rehabilitation. METHODS: We conducted a wide database search. All studies were independently screened by 2 reviewers (XW and YF), with a third reviewer (BY) involved in resolving discrepancies. The final included studies were rated according to their level of clinical evidence based on their correlation with clinical scales (with the same tasks or the same evaluation criteria). One reviewer (XW) extracted data on publication, demographic information, compensation types, sensors used for compensation assessment, compensation measurements, and statistical or artificial intelligence methods. Accuracy was checked by another reviewer (YF). Four research questions were presented. For each question, the data were synthesized and tabulated, and a descriptive summary of the findings was provided. The data were synthesized and tabulated based on each research question. RESULTS: A total of 72 studies were included in this review. In all, 2 types of compensation were identified: disuse of the affected upper limb and awkward use of the affected upper limb to adjust for limited strength, mobility, and motor control. Various models and quantitative measurements have been proposed to characterize compensation. Body-worn technology (25/72, 35% studies) was the most used sensor technology to assess compensation, followed by marker-based motion capture system (24/72, 33% studies) and marker-free vision sensor technology (16/72, 22% studies). Most studies (56/72, 78% studies) used statistical methods for compensation assessment, whereas heterogeneous machine learning algorithms (15/72, 21% studies) were also applied for automatic detection of compensatory movements and postures. CONCLUSIONS: This systematic review provides insights for future research on technology-based compensation assessment and detection in stroke UE rehabilitation. Technology-based compensation assessment and detection have the capacity to augment rehabilitation independent of the constant care of therapists. The drawbacks of each sensor in compensation assessment and detection are discussed, and future research could focus on methods to overcome these disadvantages. It is advised that open data together with multilabel classification algorithms or deep learning algorithms could benefit from automatic real time compensation detection. It is also recommended that technology-based compensation predictions be explored.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,016 | 0,088 |
| Méta-épidémiologie (sens strict) | 0,002 | 0,002 |
| Méta-épidémiologie (sens large) | 0,010 | 0,008 |
| Bibliométrie | 0,014 | 0,015 |
| Études des sciences et des technologies | 0,001 | 0,001 |
| Communication savante | 0,004 | 0,004 |
| Science ouverte | 0,003 | 0,002 |
| Intégrité de la recherche | 0,003 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,003 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».