Patients With Femoral Neck Fractures Are at Risk for Conversion to Arthroplasty After Internal Fixation: A Machine‐learning Algorithm
Notice bibliographique
Résumé
BACKGROUND: Femoral neck fractures are common and are frequently treated with internal fixation. A major disadvantage of internal fixation is the substantially high number of conversions to arthroplasty because of nonunion, malunion, avascular necrosis, or implant failure. A clinical prediction model identifying patients at high risk of conversion to arthroplasty may help clinicians in selecting patients who could have benefited from arthroplasty initially. QUESTION/PURPOSE: What is the predictive performance of a machine-learning (ML) algorithm to predict conversion to arthroplasty within 24 months after internal fixation in patients with femoral neck fractures? METHODS: We included 875 patients from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial. The FAITH trial consisted of patients with low-energy femoral neck fractures who were randomly assigned to receive a sliding hip screw or cancellous screws for internal fixation. Of these patients, 18% (155 of 875) underwent conversion to THA or hemiarthroplasty within the first 24 months. All patients were randomly divided into a training set (80%) and test set (20%). First, we identified 27 potential patient and fracture characteristics that may have been associated with our primary outcome, based on biomechanical rationale and previous studies. Then, random forest algorithms (an ML learning, decision tree-based algorithm that selects variables) identified 10 predictors of conversion: BMI, cardiac disease, Garden classification, use of cardiac medication, use of pulmonary medication, age, lung disease, osteoarthritis, sex, and the level of the fracture line. Based on these variables, five different ML algorithms were trained to identify patterns related to conversion. The predictive performance of these trained ML algorithms was assessed on the training and test sets based on the following performance measures: (1) discrimination (the model's ability to distinguish patients who had conversion from those who did not; expressed with the area under the receiver operating characteristic curve [AUC]), (2) calibration (the plotted estimated versus the observed probabilities; expressed with the calibration curve intercept and slope), and (3) the overall model performance (Brier score: a composite of discrimination and calibration). RESULTS: None of the five ML algorithms performed well in predicting conversion to arthroplasty in the training set and the test set; AUCs of the algorithms in the training set ranged from 0.57 to 0.64, slopes of calibration plots ranged from 0.53 to 0.82, calibration intercepts ranged from -0.04 to 0.05, and Brier scores ranged from 0.14 to 0.15. The algorithms were further evaluated in the test set; AUCs ranged from 0.49 to 0.73, calibration slopes ranged from 0.17 to 1.29, calibration intercepts ranged from -1.28 to 0.34, and Brier scores ranged from 0.13 to 0.15. CONCLUSION: The predictive performance of the trained algorithms was poor, despite the use of one of the best datasets available worldwide on this subject. If the current dataset consisted of different variables or more patients, the performance may have been better. Also, various reasons for conversion to arthroplasty were pooled in this study, but the separate prediction of underlying pathology (such as, avascular necrosis or nonunion) may be more precise. Finally, it may be possible that it is inherently difficult to predict conversion to arthroplasty based on preoperative variables alone. Therefore, future studies should aim to include more variables and to differentiate between the various reasons for arthroplasty. LEVEL OF EVIDENCE: Level III, prognostic study.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,005 | 0,015 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,001 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».