MétaCan
Menu
Retour à la cohorte
Enregistrement W4283581528 · doi:10.1016/j.hroo.2022.06.008

Integration of 3D nuclear imaging in 3D mapping system for ventricular tachycardia ablation in patients with implanted devices: Perfusion/voltage retrospective assessment of scar location

2022· article· en· W4283581528 sur OpenAlexafffund
Bernard Thibault, Louis‐Philippe Richer, Luke C. McSpadden, Kyungmoo Ryu, Martín Aguilar, Julia Cadrin‐Tourigny, Rafik Tadros, Blandine Mondésert, Léna Rivard, Katia Dyrda, Marc Dubuc, Laurent Macle, Mario Talajic, Paul Khairy, Peter G. Guerra, Denis Roy, Jean‐Pierre Grégoire, François Harel

Notice bibliographique

RevueHeart Rhythm O2 · 2022
Typearticle
Langueen
DomaineMedicine
ThématiqueCardiac Arrhythmias and Treatments
Établissements canadiensUniversité de MontréalMontreal Heart Institute
Organismes subventionnairesSt. Jude MedicalPfizerInstitut de Cardiologie de MontréalServierBoston Scientific CorporationAbbott Laboratories
Mots-clésMedicineVentricular tachycardiaAblationNuclear medicineCatheter ablationPerfusionMyocardial perfusion imagingSpect imagingRadiologyInternal medicine

Résumé

récupéré en direct d'OpenAlex

BackgroundThe identification of low-voltage proarrhythmic areas for catheter ablation of scar-mediated ventricular tachycardia (VT) remains challenging. Integration of myocardial perfusion imaging (single-photon emission computed tomography/computed tomography; SPECT/CT) and electroanatomical mapping (EAM) may improve delineation of the arrhythmogenic substrate.ObjectiveTo assess the feasibility of SPECT/CT image integration with voltage maps using the EnSite Precision system (Abbott) in patients undergoing scar-mediated VT ablation.MethodsPatients underwent SPECT/CT imaging prior to left ventricular (LV) EAM with the EnSite Precision mapping system. The SPECT/CT, EAM data, and ablation lesions were retrospectively co-registered in the EnSite Precision system and exported for analysis. Segmental tissue viability scores were calculated based on SPECT/CT perfusion and electrogram bipolar voltage amplitude. Concordance, specificity, and sensitivity between the 2 modalities as well as the impact of SPECT/CT spatial resolution were evaluated.ResultsTwenty subjects (95% male, 67 ± 7 years old, left ventricular ejection fraction 36% ± 11%) underwent EAM and SPECT/CT integration. A concordance of 70% was found between EAM and SPECT/CT for identification of cardiac segments as scar vs viable, with EAM showing a 68.5% sensitivity and 76.4% specificity when using SPECT/CT as a gold standard. Projection on low-resolution 3D geometries led to an average decrease of 38% ± 22% of the voltage points used.ConclusionThe study demonstrated the feasibility of integrating SPECT/CT with EAM performed retrospectively for characterization of anatomical substrates during VT ablation procedures. The identification of low-voltage proarrhythmic areas for catheter ablation of scar-mediated ventricular tachycardia (VT) remains challenging. Integration of myocardial perfusion imaging (single-photon emission computed tomography/computed tomography; SPECT/CT) and electroanatomical mapping (EAM) may improve delineation of the arrhythmogenic substrate. To assess the feasibility of SPECT/CT image integration with voltage maps using the EnSite Precision system (Abbott) in patients undergoing scar-mediated VT ablation. Patients underwent SPECT/CT imaging prior to left ventricular (LV) EAM with the EnSite Precision mapping system. The SPECT/CT, EAM data, and ablation lesions were retrospectively co-registered in the EnSite Precision system and exported for analysis. Segmental tissue viability scores were calculated based on SPECT/CT perfusion and electrogram bipolar voltage amplitude. Concordance, specificity, and sensitivity between the 2 modalities as well as the impact of SPECT/CT spatial resolution were evaluated. Twenty subjects (95% male, 67 ± 7 years old, left ventricular ejection fraction 36% ± 11%) underwent EAM and SPECT/CT integration. A concordance of 70% was found between EAM and SPECT/CT for identification of cardiac segments as scar vs viable, with EAM showing a 68.5% sensitivity and 76.4% specificity when using SPECT/CT as a gold standard. Projection on low-resolution 3D geometries led to an average decrease of 38% ± 22% of the voltage points used. The study demonstrated the feasibility of integrating SPECT/CT with EAM performed retrospectively for characterization of anatomical substrates during VT ablation procedures.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: Observationnel
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,021
Score d'incertitude au seuil0,465

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,001
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,007
Tête enseignante GPT0,247
Écart entre enseignants0,240 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations3
Publié2022
Routes d'admission2
Résumé présentoui

Explorer davantage

Même revueHeart Rhythm O2Même sujetCardiac Arrhythmias and TreatmentsTravaux en français237 207