MétaCan
Menu
Retour à la cohorte
Enregistrement W4287539881

Prostatic Artery Embolization for Benign Prostatic Hyperplasia: A Health Technology Assessment.

2021· article· en· W4287539881 sur OpenAlexaboutno aff

Notice bibliographique

RevuePubMed · 2021
Typearticle
Langueen
DomaineMedicine
ThématiqueUrinary Bladder and Prostate Research
Établissements canadiensnon disponible
Organismes subventionnairesnon disponible
Mots-clésMedicineProstatectomyProstateTransurethral resection of the prostateRandomized controlled trialGrading (engineering)Systematic reviewObservational studyHyperplasiaUrologyBenign prostatic hyperplasia (BPH)SurgeryMEDLINEInternal medicine
DOInon disponible

Résumé

récupéré en direct d'OpenAlex

BACKGROUND: Benign prostatic hyperplasia (BPH) is a noncancerous enlargement of the prostate that commonly affects older people with prostates and may lead to obstructive urinary symptoms. Symptoms may initially be mild but tend to worsen over time. Prostatic artery embolization (PAE) is an endovascular procedure to treat BPH, wherein an interventional radiologist inserts a catheter into the patient to inject tiny particles intended to reduce blood flow to the enlarged prostate, causing it to shrink in size. We conducted a health technology assessment on PAE for people with BPH, which included an evaluation of effectiveness, safety, cost-effectiveness, the budget impact of publicly funding PAE, and patient preferences and values. METHODS: We performed a systematic literature search of the clinical evidence. We assessed the risk of bias of each included study using the Cochrane Risk of Bias tool for randomized controlled trials (RCTs) and the Risk of Bias in Nonrandomized Studies-of Interventions (ROBINS-I) tool for observational studies. We assessed the quality of the body of evidence according to the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) Working Group criteria. We performed a systematic review of the economic literature. We then assessed the cost-effectiveness of PAE compared with alternative treatments (i.e., transurethral resection of the prostate [TURP] or open simple prostatectomy [OSP]) using a Markov microsimulation model. The analysis was conducted from the Ontario Ministry of Health perspective over a time horizon of 6.5 years. We also analyzed the budget impact of publicly funding PAE in people with moderate to severe BPH in Ontario. RESULTS: We included six studies in our systematic review. Four RCTs and one observational study compared PAE with TURP, and one observational study compared PAE with OSP. All studies had considerable risk-of-bias concerns. PAE may improve BPH symptoms and urodynamic measures, but we are uncertain whether PAE achieves better results than TURP (GRADE: Very low to Low). Compared with TURP, PAE may result in higher patient satisfaction and fewer adverse events (GRADE: Not assessed). Compared with OSP, PAE may result in smaller improvements in BPH symptoms and urodynamic measures and may lead to fewer adverse events, but the evidence is very uncertain (GRADE: Very low).We did not find any published cost-effectiveness studies in the economic literature review. Our primary economic evaluation showed that, compared with TURP, PAE has an incremental cost of $328 (95% CrI: -$686 to $1,423) and a very small incremental quality-adjusted life-year (QALY) of 0.007 (95% CrI: -0.004 to 0.018). The resulting incremental cost-effectiveness ratio (ICER) of PAE versus TURP is $44,930 per QALY gained. At the commonly used willingness-to-pay values of $50,000 and $100,000 per QALY, the cost-effectiveness of PAE is uncertain (52% and 68% probability, respectively, of being cost-effective compared with TURP). In a scenario analysis, we compared PAE with OSP for individuals with large prostates (who may be ineligible for TURP). We found that PAE is less costly (-$1,231; 95% CrI: -$2,457 to $69) and less effective (-0.12 QALYs; 95% CrI: -0.18 to -0.04). The resulting ICER of PAE versus OSP is $10,241 saved per QALY lost. At the commonly used willingness-to-pay value of $50,000 per QALY, PAE is unlikely to be cost-effective (2% probability of being cost-effective compared with OSP). Assuming a low uptake (i.e., an additional 10 to 50 procedures per year in years 1 to 5), we estimated that publicly funding PAE in Ontario would lead to an additional cost of about $11,400 over the next 5 years.People we spoke with who have lived experience with BPH reported on the negative impact it can have on their quality of life. Those who had received PAE reported a positive experience with the procedure and meaningful improvement in their symptoms. CONCLUSIONS: Prostatic artery embolization may improve BPH symptoms and urodynamic measures, but we are uncertain if the procedure results in similar outcomes to those of TURP. Based on one observational study, PAE may result in smaller improvements compared with OSP, but we are very uncertain of the evidence. Compared with TURP and OSP, PAE may result in fewer adverse events. Longer-term comparative studies are needed to assess the durability and long-term adverse events of PAE, the potential need for reintervention after PAE, and how PAE compares with other available BPH treatment options.We found the cost-effectiveness of PAE compared with TURP to be uncertain. Also, PAE is unlikely to be cost-effective compared with OSP. If PAE is publicly funded in Ontario, the budget impact is estimated to be small over the next 5 years.People who have lived experience with BPH reported that PAE improves quality of life and reduces negative symptoms of BPH.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,031
score de la tête « metaresearch » (Gemma)0,094
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Revue systématique · Signal consensuel: aucune
GenreSignal candidat: Synthèse · Signal consensuel: Synthèse
Score de désaccord entre enseignants0,079
Score d'incertitude au seuil0,212

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0310,094
Méta-épidémiologie (sens strict)0,0020,001
Méta-épidémiologie (sens large)0,0060,012
Bibliométrie0,0160,015
Études des sciences et des technologies0,0010,001
Communication savante0,0050,002
Science ouverte0,0020,003
Intégrité de la recherche0,0020,003
Charge utile insuffisante (le modèle a refusé de juger)0,0050,001

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,047
Tête enseignante GPT0,350
Écart entre enseignants0,303 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeRevue systématique
Domainenon disponible
GenreSynthèse

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations9
Publié2021
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revuePubMedMême sujetUrinary Bladder and Prostate ResearchTravaux en français237 207