Alignment Between Heart Rate Variability From Fitness Trackers and Perceived Stress: Perspectives From a Large-Scale In Situ Longitudinal Study of Information Workers
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
Background Stress can have adverse effects on health and well-being. Informed by laboratory findings that heart rate variability (HRV) decreases in response to an induced stress response, recent efforts to monitor perceived stress in the wild have focused on HRV measured using wearable devices. However, it is not clear that the well-established association between perceived stress and HRV replicates in naturalistic settings without explicit stress inductions and research-grade sensors. Objective This study aims to quantify the strength of the associations between HRV and perceived daily stress using wearable devices in real-world settings. Methods In the main study, 657 participants wore a fitness tracker and completed 14,695 ecological momentary assessments (EMAs) assessing perceived stress, anxiety, positive affect, and negative affect across 8 weeks. In the follow-up study, approximately a year later, 49.8% (327/657) of the same participants wore the same fitness tracker and completed 1373 EMAs assessing perceived stress at the most stressful time of the day over a 1-week period. We used mixed-effects generalized linear models to predict EMA responses from HRV features calculated over varying time windows from 5 minutes to 24 hours. Results Across all time windows, the models explained an average of 1% (SD 0.5%; marginal R2) of the variance. Models using HRV features computed from an 8 AM to 6 PM time window (namely work hours) outperformed other time windows using HRV features calculated closer to the survey response time but still explained a small amount (2.2%) of the variance. HRV features that were associated with perceived stress were the low frequency to high frequency ratio, very low frequency power, triangular index, and SD of the averages of normal-to-normal intervals. In addition, we found that although HRV was also predictive of other related measures, namely, anxiety, negative affect, and positive affect, it was a significant predictor of stress after controlling for these other constructs. In the follow-up study, calculating HRV when participants reported their most stressful time of the day was less predictive and provided a worse fit (R2=0.022) than the work hours time window (R2=0.032). Conclusions A significant but small relationship between perceived stress and HRV was found. Thus, although HRV is associated with perceived stress in laboratory settings, the strength of that association diminishes in real-life settings. HRV might be more reflective of perceived stress in the presence of specific and isolated stressors and research-grade sensing. Relying on wearable-derived HRV alone might not be sufficient to detect stress in naturalistic settings and should not be considered a proxy for perceived stress but rather a component of a complex phenomenon.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle