MétaCan
Menu
Retour à la cohorte
Enregistrement W4294589041 · doi:10.1088/0026-1394/59/1a/08013

Key comparison study on peptide purity - hexapeptide of HbA0

2022· article· en· W4294589041 sur OpenAlex

Pourquoi ce travail est dans la base

Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.

affAu moins un auteur déclare une institution canadienne dans l'instantané OpenAlex épinglé.

Notice bibliographique

RevueMetrologia · 2022
Typearticle
Langueen
DomainePhysics and Astronomy
ThématiqueRadioactive Decay and Measurement Techniques
Établissements canadiensNational Research Council Canada
Organismes subventionnairesnon disponible
Mots-clésMetrologyMutual recognitionNational standardAmino acid analysisMass fractionStandard uncertaintyChromatographyChemistryMathematicsMeasurement uncertaintyStatisticsAmino acidBusinessFood scienceBiochemistry

Résumé

récupéré en direct d'OpenAlex

Main text Under the auspices of the Protein Analysis Working Group (PAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a key comparison, CCQM-K115.2018, was coordinated by the Bureau International des Poids et Mesures (BIPM), the Health Sciences Authority (HSA) of Singapore and the Chinese National Institute of Metrology (NIM). Ten Metrology Institutes or Designated Institutes and the BIPM participated. Participants were required to assign the mass fraction of the hexapeptide of HbA0 (VE) present as the main component in the comparison sample for CCQM-K115.2018. The comparison samples were prepared by HSA/BIPM from synthetic VE purchased from a commercial supplier and used as provided without further treatment or purification. VE was selected to be representative of the performance of a laboratory's measurement capability for the purity assignment of chemically synthesized peptides of known sequence, without cross-links, up to 5 kDa and without modification. It was anticipated to provide an analytical measurement challenge representative for the value-assignment of compounds of broadly similar structural characteristics. The majority of participants used amino acid analysis (PICAA) with a correction for structurally-related peptide impurities approach as the amount of material that had been provided to each participant (25 mg) was insufficient to perform a full mass balance based characterization of the material by a participating laboratory. The coordinators, the BIPM, the HSA and the NIM, were the laboratories to use the mass balance approach as they had more material available. It was decided to propose KCRVs for both the VE mass fraction and the mass fraction of the peptide related impurities as indispensable contributor regardless of the use of PICAA, mass balance or any other approach to determine the VE purity. This allowed participants to demonstrate the efficacy of their implementation of the approaches used to determine the VE mass fraction. In particular, it allowed participants to demonstrate the efficacy of their implementation of peptide related impurity identification and quantification. More detailed studies on the identification/quantification of peptide related impurities revealed that the integrity of the impurity profile of the related peptide impurities obtained by the participant is crucial for the impact on accuracy of the VE mass fraction assignment. The assessment of the mass fraction of peptide impurities is based on the assumption that only the most consistent set of results is taken for the calculation of the KCRV PepImp . The sum of the combined cis/trans VE depsipeptide impurities (only identified/quantified by NRC and confirmed by BIPM and HSA) and mass fractions of peptide related impurities that have been identified by at least two participants have been used to establish the KCRV PepImp . The KCRV PepImp of 53.0 mg/g is associated with a corresponding expanded uncertainty of 17.3 mg/g ( k = 2) providing a more realistic basis of evaluation for the capabilities of the participants to identify/quantify peptide related impurities. Inspection of the degree of equivalence plots for the mass fraction of peptide impurities and additional information obtained from the peptide related impurity profile indicates that in all cases the major related peptide impurity, VE depsipeptide, has not been identified. The VE depsipeptide impurity was initially and uniquely identified and quantified by the NRC by the use of 1 H-NMR. The related peptide impurity mass fraction results of only four participants (NRC, LGC, LNE and HSA) are in agreement with the KCRV PepImp . The NRC has identified and quantified the VE depsipeptide whereas the LGC, LNE and HSA have not identified the VE depsipeptide but accounted for that contribution. The approach selected to obtain a KCRV VE for the mass fraction of VE is based on a mass balance calculation that takes into account the most consistent set of results for the peptide related impurities KCRV PepImp , TFA mass fraction and the water mass fraction. The KCRV VE for CCQM-K115.2018 is 613 mg/g with a corresponding expanded uncertainty of the KCRV VE of 20 mg/g ( k = 2). To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/ . The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: Observationnel
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,148
Score d'incertitude au seuil0,703

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0010,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0010,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,042
Tête enseignante GPT0,306
Écart entre enseignants0,265 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle