The Supply Side of Coagulation: Fibrinogen and Bleeding in Liver Disease and Transplantation
Notice bibliographique
Résumé
In this issue of Transplantation, Carrier et al1 describe a study that assesses the effect of preoperative fibrinogen levels on perioperative bleeding and outcomes. In 613 patients with end-stage liver disease who underwent liver transplantation between 2008 and 2019, preoperative low fibrinogen levels were associated with more blood loss but not worse 1-y survival in univariate and multivariate statistical models. This effect was most prominent when fibrinogen levels were below 3 g/L before surgery. In any model of coagulation, fibrinogen is the substrate required to create an effective clot and provide hemostasis. Like most components of hemostasis, fibrinogen is synthesized by the liver and reduced in severe liver disease. Additionally, and maybe more commonly‚ dysfibrinogenemia occurs in liver disease resulting in defects of the fibrinogen structure with undetermined effects on hemostasis.2 The coagulation abnormalities associated with liver disease result in dysbalanced hemostasis that can cause impaired clot formation or excessive thrombosis. Conventional coagulation tests cannot detect this dysbalanced hemostasis‚ as they measure only (a part of) the procoagulant side of hemostasis. Viscoelastic testing, now routinely used in many transplant centers‚ may provide a better assessment of all aspects of clot formation by creating a visual representation of changes in the viscosity of blood when a clot forms. Viscoelastic testing can guide transfusion management in many clinical scenarios‚ including liver transplantation‚ but possibly, more importantly, allows us to identify patients who are hypercoagulable even when the conventional coagulation tests are abnormally high. The results of Carrier et al suggest that low preoperative fibrinogen levels may be an indicator that a patient is at risk for increased intraoperative bleeding. This may be particularly useful if perioperative viscoelastic testing is not used or available as with the study center. This risk of bleeding increased when fibrinogen levels were below 3 g/L before surgery, a level that is far higher than what has traditionally been considered a concerning threshold. Most experts and societies, for example, the review on perioperative coagulation management in liver transplant recipients by Bezinover et al here in Transplantation in 2018,3 recommend fibrinogen concentrate and/or cryoprecipitate transfusion for fibrinogen levels below 1.5 to 2 g/L. Although raising new questions, the present study does not provide enough evidence to change this recommendation at this time. An association with bleeding (even in a multivariate model) does not necessarily mean that replacing fibrinogen with levels over 3 g/L will reduce the risk of bleeding. The assumption is that fibrinogen levels that are below 3 g/L before surgery may decrease more during transplantation to a level that actually impairs hemostasis. Excessive transfusion of cryoprecipitate (and, to a lesser degree, fibrinogen concentrates) is not without risk and may increase the risk of thromboembolic complications.4 The results by Carrier et al are raising new questions about fibrinogen thresholds and may provide the impetus for future (prospective) studies but should not necessarily change our current management. The Centre Hospitalier de L’Universite de Montreal (CHUM) has demonstrated for many years with great success what can be achieved with a concerted effort to reduce blood transfusion5: More than 70% of the patients in the present study did not receive any red blood cell transfusion at all! The center undertakes a number of interventions to achieve these remarkable results. For example, over 50% of the patients in this study underwent phlebotomy at the beginning of surgery. I am not aware of any other center that implemented such a vigorous and successful program to reduce blood transplantation. Unfortunately, this also limits the generalizability of the present study (and reduces the statistical power of the study). Furthermore, because viscoelastic testing was not used in this study, we do not know if lower preoperative fibrinogen levels result in deficient fibrinogen contribution to clot strength later during surgery (assessed, for example, using fibrinogen assays such as FIBTEM with rotational thromboelastometry, ROTEM). In summary, Carrier et al provide important insight into the role of fibrinogen in achieving hemostasis during and good outcomes after liver transplantation. Their data encourage us to check for fibrinogen levels whenever we measure conventional or viscoelastic coagulation tests and design future randomized trials of fibrinogen replacement in liver transplantation.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,007 | 0,021 |
| Méta-épidémiologie (sens strict) | 0,002 | 0,001 |
| Méta-épidémiologie (sens large) | 0,003 | 0,002 |
| Bibliométrie | 0,005 | 0,003 |
| Études des sciences et des technologies | 0,002 | 0,003 |
| Communication savante | 0,006 | 0,004 |
| Science ouverte | 0,003 | 0,002 |
| Intégrité de la recherche | 0,010 | 0,013 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,004 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».