Levonorgestrel-Releasing Intrauterine System (52 mg) for Idiopathic Heavy Menstrual Bleeding: A Health Technology Assessment.
Notice bibliographique
Résumé
BACKGROUND: Heavy menstrual bleeding affects as many as one in three women and has negative physical, economic, and psychosocial impacts including activity limitations and reduced quality of life. The goal of treatment is to make menstruation manageable, and options include medical therapy or surgery such as endometrial ablation or hysterectomy. This review examined the evidence of effectiveness and cost-effectiveness of the 52-mg levonorgestrel-releasing intrauterine system (LNG-IUS) as a treatment alternative for idiopathic heavy menstrual bleeding. METHODS: We conducted a systematic review of the clinical and economic evidence comparing LNG-IUS with usual medical therapy, endometrial ablation, or hysterectomy. Medline, EMBASE, Cochrane, and the Centres for Reviews and Dissemination were searched from inception to August 2015. The quality of the evidence was assessed according to the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) Working Group criteria. We also completed an economic evaluation to determine the cost-effectiveness and budget impact of the LNG-IUS compared with endometrial ablation and with hysterectomy. The economic evaluation was conducted from the perspective the Ontario Ministry of Health and Long-Term Care. RESULTS: Relevant systematic reviews (n = 18) returned from the literature search were used to identify eligible randomized controlled trials, and 16 trials were included. The LNG-IUS improved quality of life and reduced menstrual blood loss better than usual medical therapy. There was no evidence of a significant difference in these outcomes compared with the improvements offered by endometrial ablation or hysterectomy. Mild hormonal side effects were the most commonly reported. The quality of the evidence varied from very low to moderate across outcomes. Results from the economic evaluation showed the LNG-IUS was less costly (incremental saving of $372 per person) and more effective providing higher quality-adjusted life years (incremental value of 0.05) compared with endometrial ablation. Similarly, the LNG-IUS costs less (incremental saving of $3,138 per person) and yields higher quality-adjusted life-years (incremental value of 0.04) compared with hysterectomy. Publicly funding LNG-IUS as an alternative to endometrial ablation and hysterectomy would result in annual cost savings of $3 million to $9 million and $0.1 million to $23 million, respectively, over the first 5 years. CONCLUSIONS: The 52-mg LNG-IUS is an effective and cost-effective treatment option for idiopathic heavy menstrual bleeding. It improves quality of life and menstrual blood loss, and is well tolerated compared with endometrial ablation, hysterectomy, or usual medical therapies.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,009 | 0,028 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,001 |
| Méta-épidémiologie (sens large) | 0,006 | 0,010 |
| Bibliométrie | 0,011 | 0,008 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,002 | 0,002 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,002 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,004 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».