Influence of digital implant analog design on the positional trueness of an analog in additively manufactured models: An in‐vitro study
Notice bibliographique
Résumé
BACKGROUND: Limited evidence exists regarding the accuracy of implant analog position in printed models, particularly when implant analogs with varying designs are used. PURPOSE: To evaluate the effect of digital implant analog (DIA) design on the trueness of their position in additively manufactured digital implant models (DIMs) and to compare with that of a conventional implant analog in a stone cast. MATERIALS AND METHODS: A dentate maxillary model with a conventional implant analog (Nobel Biocare Implant Replica 4.3 mm CC RP) at left second premolar site was digitized by using a laboratory scanner (3Shape D2000) and a (SB) scan body to generate the master standard tessellation language (STL) file (M0). 12 custom trays were fabricated on M0 file and conventional polyvinylsiloxane impressions of the model were made. All impressions were poured after inserting conventional implant analogs (Nobel RP Implant Replica) (Group A). Model was then digitized with an intraoral scanner (TRIOS 3) and the same SB, and DIMs with three different DIA designs (Nobel Biocare [Group B], Elos [Group C], and NT-trading [Group D]) were generated (Dental System-Model Builder). 12 DIMs of each design were additively manufactured and corresponding DIAs were inserted. All models were digitized by using the same laboratory scanner and SB, and these STLs were transferred to a 3D analysis software (Geomagic Control X), where the STL files of the models were superimposed over M0. Linear and 3D deviations at three selected points on SB (implant-abutment connection, most cervical point on SB, and most coronal point on SB) as well as angular deviations on two planes (buccolingual and mesiodistal) were calculated. Analysis of variance (ANOVA) and Bonferroni corrected t-tests were used to analyze the trueness of implant analog positions (α = 0.05). RESULTS: The interaction of main effects significantly affected linear (p < 0.001) and angular deviations (p = 0.020). At point 1, group D had higher deviations than groups A and B (p ≤ 0.015). In addition, groups A and D had higher deviations than group B at point 4 (p < 0.001). While group C had similar linear deviations to those of other groups at point 1 and point 4 (p ≥ 0.192), the differences among test groups at point 2 were nonsignificant (p ≥ 0.276). Group B had lower angular deviations than groups C (p = 0.039) and D (p = 0.006) on buccolingual plane. CONCLUSIONS: Analog design affected the trueness of analog position as proprietary, pressure/friction fit DIA (group B) had higher linear trueness than screw-retained DIA (Group D) and conventional implant analog (group A). In addition, pressure/friction fit DIA had the highest angular trueness among tested DIAs.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,004 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,001 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,001 | 0,000 |
| Science ouverte | 0,000 | 0,001 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».