Quantitative Analysis of H+ Transportation of Nafion film on Different Substrate using Planar Inter Digitated Electrodes
Notice bibliographique
Résumé
Introduction: Ionomer thin-film gained attraction because of their thickness- and morphology-dependent changes in ionic conductivity. In a fuel cell catalyst layer, ionomer thin films coating the carbon-supported Pt-based catalysts (Pt/C) is distributed in spatially heterogeneous manner with variation in thickness and connectivity. Thus, it is difficult to clarify the quantitative attribution of the true source of effective proton resistance among Pt and carbon-support. To evaluate the quantitative attribution of proton conductivity of a thin-film ionomer on relevant substrates (e.g., carbon), we have fabricated specially designed interdigitated electrodes (IDEs) to accommodate different substrates upon which ionomer film is coated. In this work, we present the Nafion (~55 nm) proton (H + ) transportation over carbon and quartz substrate in N 2 atmosphere. Also, we will discuss the true attribution of substrate-dependence to estimate the Nafion’s thin film conductivity. Experimental: Interdigitated electrodes (IDEs) with and without carbon pad were fabricated in clean room facilities. To prepare IDEs, the patterned carbon structure was developed and pyrolyzed at 1000 ºC in 2% H 2 /N 2 gas before the Pt deposition. 1.2% Nafion dispersion was spin coated and dried at 40ºC under vacuum before electrochemical impedance spectroscopy (EIS) measurement in N 2 atmosphere. Relative humidity (RH) dependence of in-plane H + resistance was obtained and discussed through EIS measurements. Results and Discussion: Figure 1 (a) and (b) shows the side view of IDEs with (Pt_C_IDE) and without carbon pad (Pt_Q_IDE), and also Nafion’s (~55 nm) H + resistance obtained from EIS measurement at various RH in N 2 atmosphere. Nyquist plot (not shown) exhibited significant difference and ascribed film resistance (Mean value) for ionomer at carbon substrate was significantly lower (one order of magnitude) compared to that at the quartz substrate, as shown in Fig. 1 (c). In case of H + resistance using Pt IDE with carbon (Pt_C_IDE), approximately 90% of the IDE area between the electrodes is carbon and the rest is quartz. Therefore, the method of estimation of Nafion’s thin film conductivity from impedance response must be reviewed carefully and will be discussed later in detail. References: [1] Y. Nagao Sci. Tech. Adv. Mater , 21 , 79 (2020). [2] X. Gao, K. Yamamoto et al. Solid State Ionics , 357 , 115456 (2020). [3] U. N. Shrivastava, D. Khattar et al. J. Electrochem. Soc. , 167 , 134520 (2020). Figure 1
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».