Prediction of Next Glucose Measurement in Hospitalized Patients by Comparing Various Regression Methods: Retrospective Cohort Study
Notice bibliographique
Résumé
Background Continuous glucose monitors have shown great promise in improving outpatient blood glucose (BG) control; however, continuous glucose monitors are not routinely used in hospitals, and glucose management is driven by point-of-care (finger stick) and serum glucose measurements in most patients. Objective This study aimed to evaluate times series approaches for prediction of inpatient BG using only point-of-care and serum glucose observations. Methods Our data set included electronic health record data from 184,320 admissions, from patients who received at least one unit of subcutaneous insulin, had at least 4 BG measurements, and were discharged between January 1, 2015, and May 31, 2019, from 5 Johns Hopkins Health System hospitals. A total of 2,436,228 BG observations were included after excluding measurements obtained in quick succession, from patients who received intravenous insulin, or from critically ill patients. After exclusion criteria, 2.85% (3253/113,976), 32.5% (37,045/113,976), and 1.06% (1207/113,976) of admissions had a coded diagnosis of type 1, type 2, and other diabetes, respectively. The outcome of interest was the predicted value of the next BG measurement (mg/dL). Multiple time series predictors were created and analyzed by comparing those predictors and the index BG measurement (sample-and-hold technique) with next BG measurement. The population was classified by glycemic variability based on the coefficient of variation. To compare the performance of different time series predictors among one another, R2, root mean squared error, and Clarke Error Grid were calculated and compared with the next BG measurement. All these time series predictors were then used together in Cubist, linear, random forest, partial least squares, and k-nearest neighbor methods. Results The median number of BG measurements from 113,976 admissions was 12 (IQR 5-24). The R2 values for the sample-and-hold, 2-hour, 4-hour, 16-hour, and 24-hour moving average were 0.529, 0.504, 0.481, 0.467, and 0.459, respectively. The R2 values for 4-hour moving average based on glycemic variability were 0.680, 0.480, 0.290, and 0.205 for low, medium, high, and very high glucose variability, respectively. The proportion of BG predictions in zone A of the Clarke Error Grid analysis was 61%, 59%, 27%, and 53% for 4-hour moving average, 24-hour moving average, 3 observation rolling regression, and recursive regression predictors, respectively. In a fully adjusted Cubist, linear, random forest, partial least squares, and k-nearest neighbor model, the R2 values were 0.563, 0.526, 0.538, and 0.472, respectively. Conclusions When analyzing time series predictors independently, increasing variability in a patient’s BG decreased predictive accuracy. Similarly, inclusion of older BG measurements decreased predictive accuracy. These relationships become weaker as glucose variability increases. Machine learning techniques marginally augmented the performance of time series predictors for predicting a patient’s next BG measurement. Further studies should determine the potential of using time series analyses for prediction of inpatient dysglycemia.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,006 | 0,011 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,001 |
| Méta-épidémiologie (sens large) | 0,001 | 0,002 |
| Bibliométrie | 0,002 | 0,002 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».