New Heat and Moisture Exchangers for Laryngectomized Patients in Germany: Mixed Methods Study on the Expected Effectiveness
Notice bibliographique
Résumé
BACKGROUND: Notwithstanding the benefits of heat and moisture exchangers (HMEs) in both clinical research and practice, a gap exists between the optimal physiological humidification created through the nasal function and the humidification capacity of HMEs for patients after total laryngectomy. In this study, 5 new HMEs (Provox Life) specialized for situational use with improved humidification capacities were evaluated. OBJECTIVE: This study aims to evaluate the effectiveness of the existing HMEs, assess the potential effectiveness of the new HMEs, and elicit expert judgments on the new HMEs' expected effectiveness and impact on health care use. METHODS: First, a rapid literature review (RLR) was performed to identify evidence on the clinical outcomes, health outcomes, and complications of HMEs in patients who underwent laryngectomy. Second, semistructured interviews with German experts (n=4) were conducted to validate the findings of the RLR and identify reasonable expectations regarding the potential of the new HMEs. Third, a structured expert elicitation among German experts (n=19) was used to generate quantitative evidence on the expected effectiveness of the new HMEs in clinical and health outcomes. RESULTS: The RLR (n=10) demonstrated that HME use by patients has advantages compared with no HME use concerning breathing resistance, tracheal dryness and irritation, mucus production and plugging, frequency of cough and forced expectorations, sleep quality, voice quality, use of physiotherapy, tracheobronchitis or pneumonia episodes, quality of life, and patient satisfaction. From the expert interviews and structured expert elicitation, it was found that, on average, experts expect that compared with the second-generation HMEs, the new HMEs will lead to a decrease in tracheal dryness or irritation (51%, SD 24%, of patients), mucus plug events (33%, SD 32%, of patients), mucus production (53%, SD 22%, of patients), physiotherapy (0.74, SD 0.70, days) and pulmonary infections (34%, SD 32%) and an increase or improvement in speech quality (25%, SD 23%, of patients), social contacts (13%, SD 18%), quality of life (33%, SD 30%), and patient satisfaction (44%, SD 30%). An improvement in breathing (53%, SD 28%, of patients) and shortness of breath (48%, SD 25%, of patients) was expected. The average number of daily cough periods and forced expectorations was expected to be 2.95 (SD 1.61) and 2.46 (SD 1.42), respectively. Experts expect that, on average, less than half of the patients will experience sleeping problems (48%, SD 22%) and psychosocial problems (24%, SD 20%). CONCLUSIONS: According to German experts, it is expected that the new HMEs with improved humidification levels will lead to additional (clinical) effectiveness on pulmonary health and an improved overall quality of life of patients compared with the currently available HMEs.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,029 | 0,033 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,001 |
| Méta-épidémiologie (sens large) | 0,001 | 0,003 |
| Bibliométrie | 0,003 | 0,002 |
| Études des sciences et des technologies | 0,001 | 0,001 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».