Tapered Titanium Cementless Total Hip Replacements
Notice bibliographique
Résumé
The 10-to-13 year performance of 307 Mallory Head cementless tapered total hip replacements in 283 patients was assessed. Eighty-five percent of patients had a diagnosis of osteoarthritis. Fifty-one percent of patients were women. The mean patient age was 64 ± 10 years. The Hex Loc cementless acetabular component and titanium alloy femoral heads were used in each patient. At final followup, 37 (13%) patients died, 32 (10%) had revision surgery, and two (1%) were lost to followup. No femoral stem was revised for aseptic loosening, but one was revised because of sepsis and one was revised because of a periprosthetic fracture. Wear, osteolysis, and loosening were problems with the Hex Loc cementless acetabular components and 31 (10%) acetabular components required revision because of these mechanisms. The mean Harris hip score at final followup of the remaining patients was 87 ± 14 points. Three percent of these patients had thigh pain. Radiographic assessment revealed that no femoral stem or acetabular socket was definitely or probably loose. Three-dimensional wear assessment using the Devane technique was 0.35 mm per year. The Mallory Head cementless, tapered femoral component performed well in the patients in the current study, but unfortunately, the clinical results were compromised by the use of a suboptimal cementless acetabular component, the use of polyethylene that was gamma-irradiated in air, and by the use of titanium alloy femoral heads. Future developments obviously will be in the areas of better acetabular component design, alternate polyethylene sterilization methods, and enhancements of the femoral stem in terms of offset choices, neck design, and perhaps ingrowth surface.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,004 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,002 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».