Comparison of Threshold Energy Calibrations of a Photon-Counting Detector and Impact on CT Reconstruction
Notice bibliographique
Résumé
Photon-counting detectors (PCDs) require a more complicated calibration process than the standard energy-integrating detectors. The first step of a PCD calibration is the threshold energy calibration. This step determines the linear pixel-by-pixel relationship between the output voltage of a PCD and the incoming photon energy. It can be performed in several ways. Three different methods were implemented, requiring only a standard X-ray source, or an X-ray source combined with K-edge materials or a PCD response model. The three resulting calibrations were first evaluated on monoenergetic and projection measurements. The impact of the threshold calibration on computed tomography (CT) images was also studied. The calibration method fitting a detector response model to polyenergetic measurements presented the best spectral accuracy when estimating monoenergetic peaks. This calibration also produced a better pixel homogeneity in an air projection. However, no significant improvement was observed in the noise power spectrum (NPS) and ring artifact evaluation of a conventional CT image for this calibration compared to a calibration providing lower spectral accuracy or lower pixel homogeneity.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».