MétaCan
Menu
Retour à la cohorte
Enregistrement W4313680701 · doi:10.1016/j.xjon.2023.01.002

Author Reply to Commentary: Thinking nonlinearly about aortic biomechanics

2023· editorial· en· W4313680701 sur OpenAlexaff
Daniella Eliathamby, Craig A. Simmons, Jennifer Chung

Notice bibliographique

RevueJTCVS Open · 2023
Typeeditorial
Langueen
DomaineMedicine
ThématiqueAortic Disease and Treatment Approaches
Établissements canadiensUniversity of TorontoTed Rogers Centre for Heart ResearchUniversity Health Network
Organismes subventionnairesnon disponible
Mots-clésAortaAortic dissectionBiomechanicsBicuspid aortic valveCardiologyScopusAneurysmConfusionMedicinePreloadAortic aneurysmInternal medicinePsychologySurgeryAnatomyMEDLINEPsychoanalysisHemodynamics

Résumé

récupéré en direct d'OpenAlex

See Commentary on page 45. See Commentary on page 45. Drs Plestis and Rajagopal1Plestis K.A. Rajagopal K. Commentary: thinking nonlinearly about aortic biomechanics.J Thorac Cardiovasc Surg Open. 2023; 13: 45-46Scopus (1) Google Scholar have provided a commentary on our study of the relationship between aortic geometry and material properties of the aorta. Unfortunately, our work was misread. Here, we will attempt to dispel any confusion by addressing each of their 4 points.1.“It is unclear what mathematical model the authors are using.” The data were not used to fit a model. As detailed in our methods,2Chung J. Lachapelle K. Wener E. Cartier R. De Varennes B. Fraser R. et al.Energy loss, a novel biomechanical parameter, correlates with aortic aneurysm size and histopathologic findings.J Thorac Cardiovasc Surg. 2014; 148: 1082-1089https://doi.org/10.1016/j.jtcvs.2014.06.021Abstract Full Text Full Text PDF PubMed Scopus (54) Google Scholar, 3Chung J.C.-Y. Wong E. Tang M. Eliathamby D. Forbes T.L. Butany J. et al.Biomechanics of aortic dissection: a comparison of aortas associated with bicuspid and tricuspid aortic valves.J Am Heart Assoc. 2020; 9: e016715https://doi.org/10.1161/JAHA.120.016715Crossref PubMed Scopus (35) Google Scholar, 4Tang M. Eliathamby D. Ouzounian M. Simmons C.A. Chung J.C.-Y. Dependency of energy loss on strain rate, strain magnitude and preload: towards development of a novel biomarker for aortic aneurysm dissection risk.J Mech Behav Biomed Mater. 2021; 124: 104736https://doi.org/10.1016/j.jmbbm.2021.104736Crossref PubMed Scopus (6) Google Scholar, 5Eliathamby D. Keshishi M. Ouzounian M. Tan K. Simmons C.A. Chung J. et al.Ascending aortic geometry and its relationship to the biomechanical properties of aortic tissue.J Thorac Cardiovasc Surg Open. 2023; 13: 32-44Scopus (3) Google Scholar we made no assumptions of material model; all measures are derived directly from stress-strain curves obtained with rigorous, physically accurate, and biologically relevant mechanical tests. The specific protocol and derivation of material properties can be found in our current and previously published work.2Chung J. Lachapelle K. Wener E. Cartier R. De Varennes B. Fraser R. et al.Energy loss, a novel biomechanical parameter, correlates with aortic aneurysm size and histopathologic findings.J Thorac Cardiovasc Surg. 2014; 148: 1082-1089https://doi.org/10.1016/j.jtcvs.2014.06.021Abstract Full Text Full Text PDF PubMed Scopus (54) Google Scholar, 3Chung J.C.-Y. Wong E. Tang M. Eliathamby D. Forbes T.L. Butany J. et al.Biomechanics of aortic dissection: a comparison of aortas associated with bicuspid and tricuspid aortic valves.J Am Heart Assoc. 2020; 9: e016715https://doi.org/10.1161/JAHA.120.016715Crossref PubMed Scopus (35) Google Scholar, 4Tang M. Eliathamby D. Ouzounian M. Simmons C.A. Chung J.C.-Y. Dependency of energy loss on strain rate, strain magnitude and preload: towards development of a novel biomarker for aortic aneurysm dissection risk.J Mech Behav Biomed Mater. 2021; 124: 104736https://doi.org/10.1016/j.jmbbm.2021.104736Crossref PubMed Scopus (6) Google Scholar, 5Eliathamby D. Keshishi M. Ouzounian M. Tan K. Simmons C.A. Chung J. et al.Ascending aortic geometry and its relationship to the biomechanical properties of aortic tissue.J Thorac Cardiovasc Surg Open. 2023; 13: 32-44Scopus (3) Google Scholar Thus, our characterization is the most general it can be and not distorted by assumptions intrinsic to a specific material model. We distill the full biaxial stress-strain curves to metrics that efficiently describe key aspects of mechanical behavior and have clinical relevance as potentially being measurable in vivo: It is neither necessary nor useful to clinicians to apply more comprehensive material models in this context.2.“Linearized elasticity can only be applied to small deformations.” We make no assumptions of linear elasticity. Plestis and Rajagopal1Plestis K.A. Rajagopal K. Commentary: thinking nonlinearly about aortic biomechanics.J Thorac Cardiovasc Surg Open. 2023; 13: 45-46Scopus (1) Google Scholar appear to have confused Young's tangential modulus. As we defined in our study, we used the tangential modulus, which is widely used in this field. This also means that their statement that tangential modulus and hysteresis are mutually exclusive is incorrect. For further explanation on these definitions, we refer the reader to our co-Principal Investigator’s textbook on biomechanics.6Ethier C.R. Simmons C.A. Introductory Biomechanics. Cambridge University Press, 2007https://doi.org/10.1017/CBO9780511809217Crossref Google Scholar The statement that energy loss/hysteresis in the aorta is “overwhelmingly derived from left ventricular function” also points to a lack of understanding of how hysteresis is measured in biaxial tensile tests. Hysteresis is an intrinsic material property of the aorta and is independent of left ventricular function.3.“Based upon an incorrect choice of model, one could potentially incorrectly identify a relationship between two variables.” We think we have adequately addressed this bullet point already.4.“To whatever extent correlations between aortic material properties and aortic geometry could exist, they are correlations without causation.” Although the fundamental pathophysiology driving aneurysm formation and biomechanics is an active area of research in our laboratory and many others, we were extremely careful to never imply causation. The relationship between an aorta's geometry and its underlying material properties is a question of large interest and importance to those with interest in aortic disease. Plestis and Rajagopal1Plestis K.A. Rajagopal K. Commentary: thinking nonlinearly about aortic biomechanics.J Thorac Cardiovasc Surg Open. 2023; 13: 45-46Scopus (1) Google Scholar demonstrate understanding that material properties may differ in aneurysms of different sizes. They assert “pathophysiological mechanisms that underlie abnormal aortic mechanics likely are the same–or at least substantially overlapping–with those that underlie aortic dilatation.” They also demonstrate understanding that “material properties are definitionally independent of material geometry.” Herein lies the crux of our study: Diameter is the standard all surgeons continue to use, including in the most recent 2022 American Heart Association/American College of Cardiology/American Association for Thoracic Surgeon aortic guidelines,7Isselbacher E.M. Preventza O. Black III, J.M. Augoustides J.G. Beck A.W. Bolen M.A. et al.2022 ACC/AHA guideline for the diagnosis and management of aortic disease: a report of the American Heart Association/American college of Cardiology Joint Committee on clinical practice guidelines.J Am Coll Cardiol. 2022; 80: e223-e393https://doi.org/10.1016/j.jacc.2022.08.004Crossref PubMed Scopus (59) Google Scholar because it can actually be routinely measured. Length has recently garnered increasing interest.5Eliathamby D. Keshishi M. Ouzounian M. Tan K. Simmons C.A. Chung J. et al.Ascending aortic geometry and its relationship to the biomechanical properties of aortic tissue.J Thorac Cardiovasc Surg Open. 2023; 13: 32-44Scopus (3) Google Scholar,8Krüger T. Forkavets O. Veseli K. Lausberg H. Vöhringer L. Schneider W. et al.Ascending aortic elongation and the risk of dissection.Eur J Cardiothorac Surg. 2016; 50: 241-247https://doi.org/10.1093/ejcts/ezw025Crossref PubMed Scopus (66) Google Scholar, 9Wu J. Zafar M.A. Li Y. Saeyeldin A. Huang Y. Zhao R. et al.Ascending aortic length and risk of aortic adverse events: the neglected dimension.J Am Coll Cardiol. 2019; 74: 1883-1894https://doi.org/10.1016/j.jacc.2019.07.078Crossref PubMed Scopus (67) Google Scholar, 10Eliathamby D. Gutierrez M. Liu A. Ouzounian M. Forbes T.L. Tan K.T. et al.Ascending aortic length and its association with type A aortic dissection.J Am Heart Assoc. 2021; 10: e020140https://doi.org/10.1161/JAHA.120.020140Crossref PubMed Scopus (9) Google Scholar Geometric variables have served cardiac surgeons reasonably well as surrogates of wall stress and disease severity. Thus, as scientists do, we used rigorous experiments to understand the actual relationships between clinically measurable metrics against tissue material properties that define failure risk. We found that there is indeed a relationship between aortic diameter and energy loss, albeit not strong, and not between length and any of the biomechanical metrics we tested. This can then be tied together with our previous work that links biomechanical metrics, including energy loss and histopathology.2Chung J. Lachapelle K. Wener E. Cartier R. De Varennes B. Fraser R. et al.Energy loss, a novel biomechanical parameter, correlates with aortic aneurysm size and histopathologic findings.J Thorac Cardiovasc Surg. 2014; 148: 1082-1089https://doi.org/10.1016/j.jtcvs.2014.06.021Abstract Full Text Full Text PDF PubMed Scopus (54) Google Scholar,3Chung J.C.-Y. Wong E. Tang M. Eliathamby D. Forbes T.L. Butany J. et al.Biomechanics of aortic dissection: a comparison of aortas associated with bicuspid and tricuspid aortic valves.J Am Heart Assoc. 2020; 9: e016715https://doi.org/10.1161/JAHA.120.016715Crossref PubMed Scopus (35) Google Scholar Therefore, for at least the above 4 interrelated issues, the Commentary is not relevant to our study. Commentary: Thinking nonlinearly about aortic biomechanicsJTCVS OpenVol. 13PreviewMutationem motus proportionalem esse vi motrici impressae, et fieri secundum lineam rectam qua vis illa imprimatur.(The change in momentum is proportional to the motive force impressed, and in a direct line along which the force is impressed.)—Isaac Newton, Philosophiae Naturalis Principia Mathematica (1687) Ut tensio, sic vis.(As the extension, so the force.)—Robert Hooke (1678) Full-Text PDF Open Access

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,001
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMéta-épidémiologie (sens strict), Charge utile insuffisante (le modèle a refusé de juger)
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Sans objet · Signal consensuel: Sans objet
GenreSignal candidat: Éditorial · Signal consensuel: Éditorial
Score de désaccord entre enseignants0,065
Score d'incertitude au seuil1,000

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0010,001
Méta-épidémiologie (sens strict)0,0010,000
Méta-épidémiologie (sens large)0,0010,000
Bibliométrie0,0000,001
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0010,001
Intégrité de la recherche0,0000,001
Charge utile insuffisante (le modèle a refusé de juger)0,0000,001

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,047
Tête enseignante GPT0,372
Écart entre enseignants0,325 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Devis d'étudeSans objet
Domainenon disponible
GenreÉditorial

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2023
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueJTCVS OpenMême sujetAortic Disease and Treatment ApproachesTravaux en français237 207