PS-BPC03-7: ARE OSCILLOMETRIC WAVEFORMS DIFFERENT IN PREGNANCY?
Notice bibliographique
Résumé
Objective: Hypertensive disorders of pregnancy are leading causes of maternal and perinatal morbidity and mortality. Automated blood pressure (BP) measurements are being used in clinical practice; however, understanding of how oscillometric waveform vary between pregnant and non-pregnant individuals remains low. Design and Methods: Pregnant individuals over 20 weeks gestational age and healthy, non-pregnant women were recruited. Healthy, non-pregnant women (HNP) were matched to healthy pregnant women (HP), and pregnant women with a hypertensive disorder of pregnancy (HDP) by age (± 10 years), arm circumference (± 6 cm), and BMI at the time of BP measurement (± 13 kg/m2). There were seven individuals in each group for a total of 21 participants. BP measurements were done per the International Organization for Standardization (ISO) protocol using a custom-built oscillometric device as the test device and 2-observer mercury auscultation as the reference measurement. Four pairs of auscultatory measurements and four oscillometric measurements were obtained for each participant. Baseline demographics, auscultatory BP and BP derived from slope-based and fixed ratio algorithms were determined. Oscillometric waveform and envelope features were compared among groups. Results: In HNP, HP, and HDP groups respectively: mean age was 31.3 ± 4.8; 32.1 ± 3.6; 32.0 ± 4.4 years; arm circumference 31.9 ± 3.3; 32.3 ± 4.9; 34.0 ± 3.3 cm; BMI 26.8 ± 3.8; 32.0 ± 7.2; 32.4 ± 3.7 kg/m2; mean auscultatory BP (systolic/diastolic) 103.3 ± 11.1/66.5 ± 7.4; 110.6 ± 4.0/56.9 ± 6.5; 132.6 ± 19.0/83.9 ± 13.3 mmHg. HDP had significantly higher auscultatory systolic (P < 0.05) and diastolic (p < 0.01) BP than the other groups. The pregnant groups (HP, HDP) had significantly higher heart rate (p < 0.01); higher pulses (p < 0.05) in the oscillometric waveform (OMV); lower average width in the pulses (p < 0.01); higher pressure amplitude at which the OMW peaks (p < 0.05) with longer time to reach this maximum pressure amplitude (p < 0.05); greater area under the curve (p < 0.01). Compared to HNP, the HDP showed significantly skewed OMW to the right (p < 0.01); greater spread in the OMW envelope (p < 0.05) and lesser random variation in the OMW envelope (p < 0.01). A typical OMV with the 3 groups superimposed is demonstrated in Figure 1. Conclusion: Significant differences in the oscillometric waveform morphology and parameters were found in pregnancy and in hypertensive disorders of pregnancy compared to healthy controls. These results suggest that pregnancy-specific algorithms may be required to optimize accuracy for oscillometric BP measurement.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,003 | 0,013 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».