Alternative methods to measure breast density in younger women
Notice bibliographique
Résumé
BACKGROUND: Breast density is a strong and potentially modifiable breast cancer risk factor. Almost everything we know about breast density has been derived from mammography, and therefore, very little is known about breast density in younger women aged <40. This study examines the acceptability and performance of two alternative breast density measures, Optical Breast Spectroscopy (OBS) and Dual X-ray Absorptiometry (DXA), in women aged 18-40. METHODS: Breast tissue composition (percent water, collagen, and lipid content) was measured in 539 women aged 18-40 using OBS. For a subset of 169 women, breast density was also measured via DXA (percent fibroglandular dense volume (%FGV), absolute dense volume (FGV), and non-dense volume (NFGV)). Acceptability of the measurement procedures was assessed using an adapted validated questionnaire. Performance was assessed by examining the correlation and agreement between the measures and their associations with known determinants of mammographic breast density. RESULTS: Over 93% of participants deemed OBS and DXA to be acceptable. The correlation between OBS-%water + collagen and %FGV was 0.48. Age and BMI were inversely associated with OBS-%water + collagen and %FGV and positively associated with OBS-%lipid and NFGV. CONCLUSIONS: OBS and DXA provide acceptable and viable alternative methods to measure breast density in younger women aged 18-40 years.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».