von Willebrand Disease in a Pediatric-based Population - Comparison of Type 1 Diagnostic Criteria and Use of the PFA-100® and a von Willebrand Factor/Collagen-binding Assay
Notice bibliographique
Résumé
Summary Definitive diagnosis of type 1 von Willebrand Disease (VWD) remains a problem. Provisional consensus guidelines for the diagnosis of definite and possible type 1 VWD were prepared by the Scientific Subcommittee on von Willebrand factor (VWF) of the Scientific and Standardization Committee (SSC) of the International Society on Thrombosis and Haemostasis (ISTH) during the 1996 annual meeting for the specific purpose of further evaluation in retrospective and prospective studies by a Working Party on Diagnostic Criteria (1996 Annual Report of the SSC/ISTH Subcommittee on VWF). In the first phase of this study, we compared 2 definitions of type 1 VWD, each with 3 criteria: significant bleeding history, laboratory investigations, and family history. Using the ISTH consensus guidelines for type 1 VWD definition, significantly fewer patients were diagnosed with definite type 1 disease as compared to our “in house” Hospital for Sick Children (HSC) criteria (4 vs. 31). While we recognize that the provisional ISTH consensus guidelines were not intended for clinical use, we believe that the results of our studies are of interest and will assist in any future refinements to the ISTH guidelines. In the second phase of this study, we investigated the utility of 2 new tests, a laboratory screening test and a functional test, for VWD in our well characterized, pediatric-based population. The Platelet Function Analyzer (PFA-100®) provides an in vitro measure of primary hemostasis under conditions of high shear, using disposable cartridges containing collagen and either epinephrine or ADP. All tested subjects with types 2 or 3 VWD had prolonged PFA-100 closure times (CTs) with both cartridge types (n = 17) and prolonged bleeding times (n = 14). In subjects with definite type 1 VWD, 20/24 (83%) had prolonged CTs with the collagen/ADP cartridge (19/24 (79%) with collagen/epinephrine), compared with 7/26 (27%) with prolonged bleeding times. In subjects with definite types 1, 2, or 3 VWD, collagen/ADP CTs were abnormal in 37/41 subjects, giving an overall sensitivity of 90%. With this high sensitivity, the PFA-100 is a better screening test for VWD than the bleeding time. We also tested a VWF collagen-binding assay (VWF:CBA) as a functional test for VWF, in comparison with the more routinely-used ristocetin cofactor assay (VWF:RCo). The VWF:CBA is based on an ELISA technique, which has the potential to be more reproducible than the VWF:RCo. We found that the VWF:CBA detected 43/49 (88%) subjects with definite types 1, 2, or 3 VWD, performing as well as the VWF:RCo, that detected 42/48 (88%). We also showed that, used in conjunction with VWF antigen levels, the VWF:CBA may be useful in classification of VWD subtypes.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».