A111 CLINICAL AND PATHOLOGICAL OUTCOMES BETWEEN WATER EXCHANGE AND AIR INSUFFLATION USING NON-SEDATED EXTENDED FLEXIBLE SIGMOIDOSCOPY FOR AVERAGE RISK COLORECTAL CANCER SCREENING: PRELIMINARY FINDINGS FROM A RANDOMIZED CONTROL TRIAL
Notice bibliographique
Résumé
Abstract Background Colorectal cancer (CRC) is Canada's third most common cancer type and represents approximately 11% of all cancer deaths. While sedated colonoscopy or flexible sigmoidoscopy (FS) continues to be considered for CRC screening, these modalities have limitations and risks. Another unevaluated screening modality, known as an extended FS (EFS), attempts to capitalize on the benefits of a FS while minimizing the risks involved with a sedated colonoscopy. EFS provides a scope-based examination up to the splenic flexure and then attempts to examine beyond, often to the point of the caecum. Providing the option for EFS may produce improvements in the patient experience and performance, which may improve the feasibility of using scope-based screening more broadly in screening programs. Purpose To determine the extent non-sedated EFS using the water exchange method (WE) is associated with a complete colon examination compared to the traditional air insufflation (AI) method using CO2 in an average-risk screening population. Method This randomized control trial included 90 non-sedated participants, screened by trained general surgery and gastroenterology clinicians at Kelowna General Hospital, British Columbia, Canada, using two different scope insufflation techniques, WE and AI. The primary outcome of interest was the cecal intubation rates (CIR), while secondary outcomes included the adenoma detection rate (ADR) and reported pain scores. Other metrics, such as patient satisfaction rates, sessile serrated adenoma detection rates (SSADR), and serrated lesion detection rates (SLDR) were also recorded. Result(s) The demographic characteristics between the WE and AI groups were statistically similar, with the mean age of participants being 58 and 57, respectively. During the study period, four endoscopists performed the EFS. There were higher initial satisfaction rates in the WE group vs the AI (95% vs 77%, satisfaction of ≥ 9/10 p = 0.028). CIR and ADR were similar between the WE and AI group (CIR = 93% vs 91%, p = 0.710), (ADR = 40% vs 34%, p = 0.660). The SSADR and SLDR were also similar between the WE and AI group (SSADR = 21% vs 14%, p = 0.408), (SLDR = 42% vs 36%, p = 0.528). Conclusion(s) EFS without sedation using either technique exceeds quality benchmarks recommended for sedated screening colonoscopy while maintaining adequate patient safety and comfort. The WE method optimizes a patient's overall experience making a strategy of average risk colorectal cancer screening with non-sedated WE EFS feasible. Please acknowledge all funding agencies by checking the applicable boxes below CAG, Other Please indicate your source of funding; Kelowna General Hospital, Interior Health Disclosure of Interest None Declared
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,005 | 0,009 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,001 |
| Méta-épidémiologie (sens large) | 0,003 | 0,003 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,001 | 0,002 |
| Communication savante | 0,001 | 0,002 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,002 | 0,002 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,004 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».