MétaCan
← tous les travaux

RETRACTED: Influence of carbon and graphene oxide nanoparticle on the adhesive properties of dentin bonding polymer: A SEM, EDX, FTIR study

2023· article· en· 16 citations· W4323920682 sur OpenAlex· 10.1177/22808000231159238

Pourquoi ce travail est-il dans la base ?

Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.

Affiliation canadienneUne personne signataire a déclaré un établissement canadien. C'est la seule voie dont dispose la base habituelle.

Dossier post-publication

OpenAlex signale ce travail comme rétracté, mais aucune notice correspondante de Retraction Watch ne figure dans cette base.

Résumé

Objective:This study was aimed at including 2.5 wt.% of carbon nanoparticles (CNPs) and graphene oxide NPs (GNPs) in a control adhesive (CA) and then investigate the effect of this inclusion on their mechanical properties and its adhesion to root dentin. Materials and methods:Scanning electron microscopy and energy dispersive X-ray (SEM-EDX) mapping were conducted to investigate the structural features and elemental distribution of CNPs and GNPs, respectively. These NPs were further characterized by Raman spectroscopy. The adhesives were characterized by evaluating their push-out bond strength (PBS), rheological properties, degree of conversion (DC) investigation, and failure type analysis. Results:The SEM micrographs revealed that the CNPs were irregular and hexagonal, whereas the GNPs were flake-shaped. EDX analysis showed that carbon (C), oxygen (O), and zirconia (Zr) were found in the CNPs, while the GNPs were composed of C and O. The Raman spectra for CNPs and GNPs revealed their characteristic bands (CNPs-D band: 1334 cm−1, GNPs-D band: 1341 cm−1, CNPs-G band: 1650 cm−1, and GNPs-G band: 1607 cm−1). The testing verified that the highest bond strength to root dentin were detected for GNP-reinforced adhesive (33.20 ± 3.55 MPa), trailed closely by CNP-reinforced adhesive (30.48 ± 3.10 MPa), while, the CA displayed lowest values (25.11 ± 3.60 MPa). The inter-group comparisons of the NP-reinforced adhesives with the CA revealed statistically significant results (p < 0.01). Failures of adhesive nature were most common in within the adhesives and root dentin. The rheological assessment results demonstrated a reduced viscosity for all the adhesives observed at advanced angular frequencies. All the adhesives verified suitable dentin interaction shown by hybrid layer and appropriate resin tag development. A reduced DC was perceived for both NP-reinforced adhesives, compared to the CA. Conclusion:The present study’s findings have demonstrated that 2.5% GNP adhesive revealed the highest, suitable root dentin interaction, and acceptable rheological properties. Nevertheless, a reduced DC was observed (matched with the CA). Prospective studies probing the influence of diverse concentrations of filler NPs on the adhesive’s mechanical properties to root dentin are recommended.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

La notice

Revue
Journal of Applied Biomaterials & Functional Materials
Thématique
Dental materials and restorations
Domaine
Dentistry
Établissements canadiens
University of Toronto
Organismes subventionnaires
King Saud University
Mots-clés
GrapheneAdhesiveMaterials scienceFourier transform infrared spectroscopyDentinNanoparticlePolymerComposite materialOxideCarbon NanoparticlesChemical engineeringNanotechnologyMetallurgyLayer (electronics)
Résumé présent dans OpenAlex
oui