PD28-07 FIRST-IN-HUMAN EXPERIENCE USING THE LITHOVUE ELITE SINGLE USE URETEROSCOPE TO MEASURE INTRARENAL PRESSURE: THE CANADIAN EXPERIENCE
Notice bibliographique
Résumé
You have accessJournal of UrologyCME1 Apr 2023PD28-07 FIRST-IN-HUMAN EXPERIENCE USING THE LITHOVUE ELITE SINGLE USE URETEROSCOPE TO MEASURE INTRARENAL PRESSURE: THE CANADIAN EXPERIENCE Ben H. Chew, Kyochul Koo, Abdulghafour Halawani, Jeddah, Saudi Arabia, Victor K. F. Wong, and Naeem Bhojani Ben H. ChewBen H. Chew More articles by this author , Kyochul KooKyochul Koo More articles by this author , Abdulghafour HalawaniAbdulghafour Halawani More articles by this author , Jeddah Jeddah More articles by this author , Saudi ArabiaSaudi Arabia More articles by this author , Victor K. F. WongVictor K. F. Wong More articles by this author , and Naeem BhojaniNaeem Bhojani More articles by this author View All Author Informationhttps://doi.org/10.1097/JU.0000000000003313.07AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract INTRODUCTION AND OBJECTIVE: Intrarenal pressure (IRP) is thought to play a role in complications following ureteroscopy. This area is poorly studied because of the difficulty in routinely measuring IRP. We report on our first-in-human experience using the LithoVue EliteTM ureteroscope (Boston Scientific). METHODS: A single-arm retrospective observational analysis was performed in 46 consecutive patients undergoing ureteroscopic lithotripsy using the LithoVue Elite™ system with pressure sensing capability between April-October, 2022 at 2 centres. A pressure bag set at 150mmHg or hand irrigation with a 60cc syringe was used for irrigation and a ureteral access sheath (UAS) was placed at the physician’s discretion. Median and maximum IRPs, and relative cumulative time exceeding 20, 40, 60, 80, 100, 120, 140, 160, and 200 mmHg per total procedure time were analyzed. The two-sample Mann-Whitney U-test was used with a statistical significance set at p<0.005. RESULTS: Median patient age and body mass index (BMI) were 62.5 (IQR 47.8–72.0) years and 29.4 (23.3–32.8) kg/m2 (Table 1). During the median total procedure time of 31.9 (IQR 17.4–44.9) minutes, median and maximum IRPs were 30.0 (IQR 21.0–51.5) and 177.0 mmHg (IQR 129.0–266.0), respectively. IRP remained below 60 mmHg 91.3% of the procedure times (Figure 1). Patients with Asian ethnicity and hypertension had higher pressures and a longer relative cumulative time≥20 mmHg compared to others, while patients with tight ureters and without UAS use exhibited longer cumulative times≥60 mmHg . The smaller 10/12 Fr UAS did not lower pressures as much as the 11/13 Fr and 12/14 Fr UAS (p<0.001). Age, pre-stenting, preoperative α-blockade, and BMI did not show any statistically significant associations with IRP. CONCLUSIONS: IRP can now be routinely measured during ureteroscopy. Patients had a median IRP of 30 mmHg and a maximum of 177 mmHg. The use of a smaller UAS (<12/14 Fr), Asian ethnicity, hypertension and tight ureters were found to have higher IRPs in our study. Source of Funding: None © 2023 by American Urological Association Education and Research, Inc.FiguresReferencesRelatedDetails Volume 209Issue Supplement 4April 2023Page: e821 Advertisement Copyright & Permissions© 2023 by American Urological Association Education and Research, Inc.MetricsAuthor Information Ben H. Chew More articles by this author Kyochul Koo More articles by this author Abdulghafour Halawani More articles by this author Jeddah More articles by this author Saudi Arabia More articles by this author Victor K. F. Wong More articles by this author Naeem Bhojani More articles by this author Expand All Advertisement PDF downloadLoading ...
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,001 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».