Methodologies for Evaluating the Usability of Rehabilitation Technologies Aimed at Supporting Shared Decision-Making: Scoping Review
Notice bibliographique
Résumé
BACKGROUND: The field of rehabilitation has seen a recent rise in technologies to support shared decision-making (SDM). Usability testing during the design process of SDM technologies is needed to optimize adoption and realize potential benefits. There is variability in how usability is defined and measured. Given the complexity of usability, a thorough examination of the methodologies used to measure usability to develop the SDM technologies used in rehabilitation care is needed. OBJECTIVE: This scoping review aims to answer the following research questions: which methods and measures have been used to produce knowledge about the usability of rehabilitation technologies aimed at supporting SDM at the different phases of development and implementation? Which parameters of usability have been measured and reported? METHODS: This review followed the Arksey and O'Malley framework. An electronic search was performed in the Ovid MEDLINE, Embase, CINAHL, and PsycINFO databases from January 2005 up to November 2020. In total, 2 independent reviewers screened all retrieved titles, abstracts, and full texts according to the inclusion criteria and extracted the data. The International Organization for Standardization framework was used to define the scope of usability (effectiveness, efficiency, and satisfaction). The characteristics of the studies were outlined in a descriptive summary. Findings were categorized based on usability parameters, technology interventions, and measures of usability. RESULTS: A total of 38 articles were included. The most common SDM technologies were web-based aids (15/33, 46%). The usability of SDM technologies was assessed during development, preimplementation, or implementation, using 14 different methods. The most frequent methods were questionnaires (24/38, 63%) and semistructured interviews (16/38, 42%). Satisfaction (27/38, 71%) was the most common usability parameter mapped to types of SDM technologies and usability evaluation methods. User-centered design (9/15, 60%) was the most frequently used technology design framework. CONCLUSIONS: The results from this scoping review highlight the importance and the complexity of usability evaluation. Although various methods and measures were shown to be used to evaluate the usability of technologies to support SDM in rehabilitation, very few evaluations used in the included studies were found to adequately span the selected usability domains. This review identified gaps in usability evaluation, as most studies (24/38, 63%) relied solely on questionnaires rather than multiple methods, and most questionnaires simply focused on the usability parameter of satisfaction. The consideration of end users (such as patients and clinicians) is of particular importance for the development of technologies to support SDM, as the process of SDM itself aims to improve patient-centered care and integrate both patient and clinician voices into their rehabilitation care.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,160 | 0,331 |
| Méta-épidémiologie (sens strict) | 0,004 | 0,003 |
| Méta-épidémiologie (sens large) | 0,011 | 0,010 |
| Bibliométrie | 0,088 | 0,061 |
| Études des sciences et des technologies | 0,005 | 0,005 |
| Communication savante | 0,014 | 0,012 |
| Science ouverte | 0,006 | 0,007 |
| Intégrité de la recherche | 0,005 | 0,003 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,005 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».