Abstract 168: Esophageal adenocarcinoma-on-a-chip; modeling patient specific disease progression and a step towards functional precision oncology
Notice bibliographique
Résumé
Abstract Introduction: Esophageal cancer causes sixth most cancer-related morbidity and mortality worldwide, with a survival rate of <20%. Incidence of esophageal adenocarcinoma (EA) subtype has been rising (>60%) in North America. Systemic docetaxel-based triplet chemotherapy represents the best standard of care, approx. 60% of patients showcasing innate chemo-resistance or developing acquired chemo-resistance. 3D organoids provide a robust and heterogeneous cell source but lack the stromal microenvironment. We established a high-fidelity, stromal-inclusive tumor-on-chip platform expanding on tumor heterogeneity with micro-physiological relevance and flexible complexity. Methods: A total of 8 (4 chemo-sensitive and 4 chemo-resistant) treatment naïve patient-derived organoids (PDOs) and matched fibroblasts were selected to develop syngeneic human esophageal microtissues (tumor and adjacent) on commercially available (Emulate), compartmentalized, porous polydimethylsiloxane (PDMS) membrane-based microfluidic device. Chips accommodate organoids-derived epithelial cells at the upper mucosal channel and matched fibroblasts at the bottom stromal channel. 3D-microtissue development on the chip and treatment-induced cytotoxicity were examined for up to 11 days. We followed the FLOT (docetaxel, oxaliplatin, and 5-fluorouracil; 1:1.7:52) based chemotherapy regime on the chip and evaluated the recapitulation of patient-specific response. Epithelial barrier integrity, adenocarcinoma-associated cellular proteins, and level of cyfra 21-1 (circulating tumor biomarker) were determined on-chip grown microtissues. Results: Real-time brightfield microscopic observations revealed that the EA chips manifest mucin production, adequate tissue tight epithelial barriers, and distinct morphological characteristics that emerged with adenocarcinoma progression. Presence of pleomorphic cells (multiple shapes and sizes), establishment of tight epithelial barriers and formation of mature microvilli was observed via electron microscopy. Patient specific tumor tissue growth were observed for maximum 12 days under a physiologically relevant media flow. Perfusion of pharmacokinetically pertinent doses of triplet chemotherapeutic compounds performed through the stromal channel and each chip recapitulated level of chemosensitivity observed in the patient. Fluorescent probes and LDH assay also demonstrated patient-specific chemo response. Confocal imaging revealed differential expression of proliferation (ki67), epithelial (CK7, E-cadherin), and mesenchymal (Vimentin) markers in each patient-derived chip. Conclusions: Human esophageal adenocarcinoma-on-a-chip is a novel, most human-relevant biomimetic platform built on a microfluidic chip and a potential alternative to inadequate pre-clinical animal models in the future. Citation Format: Sanjima Pal, Elee Shimshoni, Salvador Flores-Torres, Julie Bérubé, Kulsum Tai, Iris Kong, Betty Giannias, Sean Hall, Nicholas Bertos, Veena Sangwan, Donald E. Ingber, Lorenzo Ferri. Esophageal adenocarcinoma-on-a-chip; modeling patient specific disease progression and a step towards functional precision oncology [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2023; Part 1 (Regular and Invited Abstracts); 2023 Apr 14-19; Orlando, FL. Philadelphia (PA): AACR; Cancer Res 2023;83(7_Suppl):Abstract nr 168.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».