MétaCan
Menu
Retour à la cohorte
Enregistrement W4362602021 · doi:10.1001/jamacardio.2023.0467

Association of the Timing and Extent of Cardiac Implantable Electronic Device Infections With Mortality

2023· article· en· W4362602021 sur OpenAlexafffundabout
Hui‐Chen Han, Jia Wang, David Birnie, Marco Alings, François Philippon, Ratika Parkash, Jaimie Manlucu, Paul Angaran, Claus Rinne, Benoit Coutu, R. Aaron Low, Vidal Essebag, Carlos A. Morillo, Jeff S. Healey, Damian Redfearn, Satish Toal, Giuliano Becker, Michel Degrâce, Bernard Thibault, Eugene Crystal, Stanley Tung, John LeMaitre, Omar Sultan, Matthew T. Bennett, Jamil Bashir, Félix Ayala-Paredes, Philippe Gervais, Leon Rioux, Martin E W Hemels, Leon Bouwels, Derek V. Exner, Paul Dorian, Stuart J. Connolly, Yves Longtin, Andrew D. Krahn

Notice bibliographique

RevueJAMA Cardiology · 2023
Typearticle
Langueen
DomaineMedicine
ThématiqueCardiac pacing and defibrillation studies
Établissements canadiensMcGill UniversityJewish General HospitalCentre Intégré de Santé et de Services Sociaux du Bas-Saint-LaurentCentre Hospitalier Universitaire de SherbrookeVancouver General HospitalSunnybrook Health Science CentreMontreal Heart InstituteQueen Elizabeth II Health Sciences CentreCégep de LévisRoyal Columbian HospitalHorizon Health NetworkKingston General HospitalQueen's UniversityLibin Cardiovascular Institute of AlbertaHealth Sciences CentreUniversity of CalgaryUniversité de MontréalChinook Regional HospitalSt. Paul's HospitalWestern UniversityPopulation Health Research InstituteSaskatchewan HealthLawson Health Research InstituteSt. Michael's HospitalRegina General HospitalUniversity of TorontoInstitut universitaire de cardiologie et de pneumologie de QuébecHamilton Health SciencesHôpital du Sacré-Cœur de MontréalMcGill University Health CentreUniversity of OttawaMcMaster UniversitySaskatchewan Health AuthorityCentre Hospitalier de l’Université de MontréalUniversité LavalUniversity of British Columbia
Organismes subventionnairesCanadian Institutes of Health Research
Mots-clésMedicineHazard ratioIncidence (geometry)Prospective cohort studyInternal medicineCohort studyComplicationSurgeryConfidence interval

Résumé

récupéré en direct d'OpenAlex

Importance: Cardiac implantable electronic device (CIED) infection is a potentially devastating complication with an estimated 12-month mortality of 15% to 30%. The association of the extent (localized or systemic) and timing of infection with all-cause mortality has not been established. Objective: To evaluate the association of the extent and timing of CIED infection with all-cause mortality. Design, Setting, and Participants: This prospective observational cohort study was conducted between December 1, 2012, and September 30, 2016, in 28 centers across Canada and the Netherlands. The study included 19 559 patients undergoing CIED procedures, 177 of whom developed an infection. Data were analyzed from April 5, 2021, to January 14, 2023. Exposures: Prospectively identified CIED infections. Main Outcomes and Measures: Time-dependent analysis of the timing (early [≤3 months] or delayed [3-12 months]) and extent (localized or systemic) of infection was performed to determine the risk of all-cause mortality associated with CIED infections. Results: Of 19 559 patients undergoing CIED procedures, 177 developed a CIED infection. The mean (SD) age was 68.7 (12.7) years, and 132 patients were male (74.6%). The cumulative incidence of infection was 0.6%, 0.7%, and 0.9% within 3, 6, and 12 months, respectively. Infection rates were highest in the first 3 months (0.21% per month), reducing significantly thereafter. Compared with patients who did not develop CIED infection, those with early localized infections were not at higher risk for all-cause mortality (no deaths at 30 days [0 of 74 patients]: adjusted hazard ratio [aHR], 0.64 [95% CI, 0.20-1.98]; P = .43). However, patients with early systemic and delayed localized infections had an approximately 3-fold increase in mortality (8.9% 30-day mortality [4 of 45 patients]: aHR, 2.88 [95% CI, 1.48-5.61]; P = .002; 8.8% 30-day mortality [3 of 34 patients]: aHR, 3.57 [95% CI, 1.33-9.57]; P = .01), increasing to a 9.3-fold risk of death for those with delayed systemic infections (21.7% 30-day mortality [5 of 23 patients]: aHR, 9.30 [95% CI, 3.82-22.65]; P < .001). Conclusions and Relevance: Findings suggest that CIED infections are most common within 3 months after the procedure. Early systemic infections and delayed localized infections are associated with increased mortality, with the highest risk for patients with delayed systemic infections. Early detection and treatment of CIED infections may be important in reducing mortality associated with this complication.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: Observationnel
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,026
Score d'incertitude au seuil0,156

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,021
Tête enseignante GPT0,294
Écart entre enseignants0,273 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations20
Publié2023
Routes d'admission3
Résumé présentoui

Explorer davantage

Même revueJAMA CardiologyMême sujetCardiac pacing and defibrillation studiesTravaux en français237 207