Optimization of the Cooling Performance of Symmetric Battery Thermal Management Systems at High Discharge Rates
Notice bibliographique
Résumé
An air cooling battery thermal management system (BTMS) is widely used in electric vehicles (EVs). In this work, numerical simulation is used to provide a greater understanding of the system efficiency of T-type symmetric air cooling BTMS (T-BTMS) and its coupled systems. For T-BTMS, the method of the coefficient of variation (MCV) is applied to evaluate the schemes with different inlet flow rates and battery clearances. It is found that optimum cooling performance and energy consumption are achieved at an internal clearance of 3 mm and an inlet air velocity of 6 m·s –1 . Further improvements in cooling performance can be realized by introducing heat transfer fins into the module. Increasing the number of fins can improve cooling performance but results in higher energy consumption. To further improve the cooling performance at high battery discharge rates, a coupled system with air cooling and liquid cooling is proposed. It is found that, at high discharge rates, the coupled system gives better cooling performance and lower energy consumption compared to uncoupled systems. When the battery module is fully discharged at the rate of 4 C, the maximum temperature of the coupled system is below the critical value of 45 °C and the maximum temperature difference is less than 5 °C.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».