Evaluating the use of methods to mitigate bias from non‐transient medications in the case‐crossover design: A systematic review
Notice bibliographique
Résumé
PURPOSE: The case-crossover design is a self-controlled study design used to compare exposure immediately preceding an event occurrence with exposure in earlier control periods. The design is most suitable for transient exposures in order to avoid biases that can be problematic when using the case-crossover design for non-transient (i.e., chronic) exposures. Our goal was to conduct a systematic review of case-crossover studies and its variants (case-time-control and case-case-time-control) in order to compare design and analysis choices by medication type. METHODS: We conducted a systematic search to identify recent case-crossover, case-time-control, and case-case-time-control studies focused on medication exposures. Articles indexed in MEDLINE and EMBASE using these study designs that were published between January 2015 and December 2021 in the English language were identified. Reviews, methodological studies, commentaries, articles without medications as the exposure of interest, and articles with no available full text were excluded. Study characteristics including study design, outcome, risk window, control window, reporting of discordant pairs, and inclusion of sensitivity analyses were summarized overall and by medication type. We further evaluated the implementation of recommended methods to account for biases introduced by non-transient exposures among articles that used the case-crossover design on a non-transient exposure. RESULTS: Of the 2036 articles initially identified, 114 articles were included. The case-crossover was the most common study design (88%), followed by the case-time-control (17%), and case-case-time-control (3%). Fifty-three percent of the articles included only transient medications, 35% included only non-transient medications, and 12% included both. Across years, the proportion of case-crossover articles evaluating a non-transient medication ranged from 30% in 2018 to 69% in 2017. We found that 41% of the articles that evaluated a non-transient medication did not apply any of the recommended methods to account for biases and more than half of which were conducted by authors with no previous publication history of case-crossover studies. CONCLUSION: Using the case-crossover design to evaluate a non-transient medication remains common in pharmacoepidemiology. Researchers should apply appropriate design and analysis choices when opting to use a case-crossover design with non-transient medication exposures.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,051 | 0,049 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,004 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; les deux têtes enseignantes s’accordent sur ce qui est montré ici.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».