MétaCan
Menu
Retour à la cohorte
Enregistrement W4379743035 · doi:10.1016/j.atssr.2023.05.008

Stent Graft Migration Causing Two Aortic Wall Injuries 10 Years After Type II Hybrid Arch Repair

2023· article· en· W4379743035 sur OpenAlexaff
David G. Guzzardi, Daniyil A. Svystonyuk, Eric Herget, Kenton Rommens, R. Scott McClure

Notice bibliographique

RevueAnnals of Thoracic Surgery Short Reports · 2023
Typearticle
Langueen
DomaineMedicine
ThématiqueAortic Disease and Treatment Approaches
Établissements canadiensLibin Cardiovascular Institute of AlbertaUniversity of CalgaryMcMaster University
Organismes subventionnairesnon disponible
Mots-clésMedicineArchStentElephant trunksDescending aortaAscending aortaAortic archSurgeryAortaThoracic aorta

Résumé

récupéré en direct d'OpenAlex

Hybrid arch repair (HAR) combines surgical reconstruction of the ascending aorta and arch debranching with stent graft deployment into the descending thoracic aorta in an effort to reduce the morbidity associated with conventional open total arch replacement. We describe a case of delayed presentation for 2 thoracic aortic wall injuries caused by stent graft migration after type II HAR. This report highlights an important late complication of HAR and the need for careful device selection. It also underlines the importance of lifelong imaging surveillance for patients undergoing complex aortic arch reconstruction. Hybrid arch repair (HAR) combines surgical reconstruction of the ascending aorta and arch debranching with stent graft deployment into the descending thoracic aorta in an effort to reduce the morbidity associated with conventional open total arch replacement. We describe a case of delayed presentation for 2 thoracic aortic wall injuries caused by stent graft migration after type II HAR. This report highlights an important late complication of HAR and the need for careful device selection. It also underlines the importance of lifelong imaging surveillance for patients undergoing complex aortic arch reconstruction. Hybrid arch repair (HAR) is an alternative consideration to conventional open total arch reconstruction (TAR). Although results are mixed,1Liu Y. Liang S. Zhang B. et al.Type II hybrid arch repair versus total arch replacement with frozen elephant trunk: a propensity score–matched analysis.Eur J Cardiothorac Surg. 2021; 60: 297-304Crossref PubMed Scopus (5) Google Scholar,2Sule J. Chua C.R. Teo C. et al.Hybrid type II and frozen elephant trunk in acute Stanford type A aortic dissections.Scand Cardiovasc J. 2022; 56: 91-99Crossref PubMed Scopus (1) Google Scholar combining great vessel debranching with endovascular stent graft deployment may mitigate perioperative morbidity relative to TAR. Still, HAR can incur stent-related issues unique to stent use: endoleak, retrograde type A aortic dissection, stent migration, and stent-induced new entry (SINE) tears. This necessitates anatomic suitability and careful device selection. We present a unique case of 2 delayed complications after type II HAR, in which stent design and stent migration contributed to aortic wall injuries of both the ascending and descending aorta. The aortic injuries were addressed in a staged hybrid approach. Given the widespread use of HAR techniques, practitioners should be aware of this potential complication and its management. A 69-year-old man first presented in 2010 with an acute DeBakey I aortic dissection. A type II HAR was successfully performed with a 28-mm 4-branched Vascutek Bavaria graft.3Milewski R.K. Szeto W.Y. Pochettino A. Moser G.W. Moeller P. Bavaria J.E. Have hybrid procedures replaced open aortic arch reconstruction in high-risk patients? A comparative study of elective open arch debranching with endovascular stent graft placement and conventional elective open total and distal arch reconstruction.J Thorac Cardiovasc Surg. 2010; 140: 590-597Abstract Full Text Full Text PDF PubMed Scopus (165) Google Scholar Using the right axillary artery and right atrium, cardioplumonary (CPB) and mild hypothermia were instituted (30 °C). A cross-clamp was placed to facilitate replacement of the ascending aorta and released before sequential debranching of the head vessels. Once the patient was weaned from CPB, a Cook Zenith TX2 thoracic stent graft (36 × 202 mm) was deployed antegrade across the arch from zones 0 to 4 (Figure 1).3Milewski R.K. Szeto W.Y. Pochettino A. Moser G.W. Moeller P. Bavaria J.E. Have hybrid procedures replaced open aortic arch reconstruction in high-risk patients? A comparative study of elective open arch debranching with endovascular stent graft placement and conventional elective open total and distal arch reconstruction.J Thorac Cardiovasc Surg. 2010; 140: 590-597Abstract Full Text Full Text PDF PubMed Scopus (165) Google Scholar The patient’s medical history was significant for gout, rheumatoid arthritis, and lupus anticoagulant. The patient did well postoperatively. Incidental note of thrombosis to the left subclavian bypass limb without sequelae was identified at 9 months on routine imaging surveillance. Three years after the index operation, a distal SINE tear in zone 4 of the descending aorta was noted on routine computed tomography imaging. The defect was small and the patient was asymptomatic, so surveillance was continued. With stable dimensions over time, computed tomography surveillance was extended to 2-year intervals. Unexpectedly, 10 years after the index surgery (78 years old), a second SINE tear was identified within the ascending aorta at zone 0C. The stent graft had migrated from its original proximal seal zone within the Bavaria graft to injure the aortic wall, causing a 1.2-cm pseudoaneurysm. The wall injury was associated with increased false lumen size within the aortic arch, having pronounced thrombus and a type IA endoleak. The aortic arch increased in diameter to 5.4 cm (previously 4.2 cm). A new type IB endoleak was also present (Figure 2A). The patient remained asymptomatic and felt well. The patient underwent urgent redo surgical ascending and aortic arch reconstruction, followed by endovascular repair of the descending aorta months later. Given the proximal location of the debranched head vessels (which complicates antegrade cerebral perfusion strategies), after safe sternal reentry, femoral-femoral CPB was instituted. With 7 minutes of pure deep hypothermic circulatory arrest (18 °C) and 20 minutes of adjunct bilateral antegrade cerebral perfusion, a 34-mm Gelweave Ante-Flo graft (Terumo Aortic) was anastomosed to the proximal aspect of the Zenith TX2 stent. The original debranched head vessel limbs were then reimplanted into the graft as an island. Postoperatively, the patient had brief aphasia secondary to a small left middle cerebral artery infarct but had full recovery. His postoperative course was otherwise unremarkable. Eleven months later (delayed because of COVID-19 protocols), the patient underwent a zone 4-5 endovascular extension with 2 GORE cTAG (Gore Medical) active control system stent grafts (31 mm × 10 cm and 37 mm × 15 cm) to exclude the residual type IB endoleak and the chronic distal pseudoaneurysm that had increased to 4.6 cm (Figure 2B). The patient’s postoperative course was remarkable for exacerbation of preexisting idiopathic normal-pressure hydrocephalus managed conservatively, with steady improvement over time. The aortic arch increases the complexity of surgical repair. Although TAR is the "gold standard," HAR with open aortic surgery and thoracic endovascular aortic repair (TEVAR) in combination has emerged as an alternative in select scenarios.3Milewski R.K. Szeto W.Y. Pochettino A. Moser G.W. Moeller P. Bavaria J.E. Have hybrid procedures replaced open aortic arch reconstruction in high-risk patients? A comparative study of elective open arch debranching with endovascular stent graft placement and conventional elective open total and distal arch reconstruction.J Thorac Cardiovasc Surg. 2010; 140: 590-597Abstract Full Text Full Text PDF PubMed Scopus (165) Google Scholar Although long-term outcomes for TAR and TEVAR are separately well delineated,4Bavaria J. Vallabhajosyula P. Moeller P. Szeto W. Desai N. Pochettino A. Hybrid approaches in the treatment of aortic arch aneurysms: postoperative and midterm outcomes.J Thorac Cardiovasc Surg. 2013; 145: S85-S90Abstract Full Text Full Text PDF PubMed Scopus (153) Google Scholar long-term outcomes for HAR, by contrast, as well as the management of late complications are less understood.5Chakos A. Jbara D. Yan T.D. Tian D.H. Long-term survival and related outcomes for hybrid versus traditional arch repair—a meta-analysis.Ann Cardiothorac Surg. 2018; 7: 319-327Crossref PubMed Scopus (26) Google Scholar Most studies are limited to small institutional series with a focus on acute or subacute events. The case herein demonstrates a multifaceted complication after HAR whereby thoracic stent migration caused 2 discrete aortic wall injuries on either side of the aortic arch in a delayed fashion, a decade after the index HAR surgery. Stent-induced wall injury has been reported to occur in up to 9% of TEVAR cases; most injuries have occurred in the setting of an acute dissection, with stents having bare springs or barbs.6Doberne J.W. Sabe A.A. Vekstein A.M. et al.Stent graft–induced aortic wall injury: incidence, risk factors, and outcomes.Ann Thorac Surg. 2022; 114: 684-692Abstract Full Text Full Text PDF PubMed Scopus (3) Google Scholar Reinterventions were required in one-third of these cases, and they occurred up to 10 years after the index procedure. Higher radial force devices and the degree of oversizing were speculated to contribute to these complications and may provide some insight into the 2 wall injuries reported in this case. Here, the use of a Cook TX2 endograft, designed as a straight conduit for the descending aorta rather than to be curved within the arch, was almost certainly a contributing factor. Migration due to an insufficiently long proximal seal on the outer curvature coupled with straightening of the stent itself likely injured the aortic wall. By contrast, endografts with enhanced arch conformability as well as alternative devices and approaches for arch reconstruction, such as the GORE TBE stent graft or Terumo Aortic RelayBranch system, have since enabled arch debranching while providing a conduit in the descending aorta that may lessen the material property differences between native aorta and stiff protheses. That 2 separate SINE tears required repair in this case presents a unique challenge for surgeons, and use of both open and endovascular strategies to address these complications supports the need for patient-specific tailoring of therapies. Joo and colleagues7Joo H.C. Youn Y.N. Kwon J.H. et al.Late complications after hybrid arch repair.J Vasc Surg. 2019; 70: 1023-1030Abstract Full Text Full Text PDF PubMed Google Scholar in a review of HAR reported that elective repair of HAR complications is preferable to either emergent surgical or conservative management. Such data, in addition to the case we present, highlight the need for ongoing, lifelong surveillance for this population of patients. This work was supported by Libin Cardiovascular Institute.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: Observationnel
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,102
Score d'incertitude au seuil0,901

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0010,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0010,001
Bibliométrie0,0000,001
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,091
Tête enseignante GPT0,382
Écart entre enseignants0,290 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2023
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueAnnals of Thoracic Surgery Short ReportsMême sujetAortic Disease and Treatment ApproachesTravaux en français237 207