Quantifying uncertainties associated with reference dosimetry in an MR‐Linac
Notice bibliographique
Résumé
Abstract Background Magnetic resonance (MR)‐guided radiation therapy provides capabilities to utilize high‐resolution and real‐time MR imaging before and during treatment, which is critical for adaptive radiotherapy. This emerging modality has been promptly adopted in the clinic settings in advance of adaptations to reference dosimetry formalism that are needed to account for the presence of strong magnetic fields. In particular, the influence of magnetic field on the uncertainty of parameters in the reference dosimetry equation needs to be determined in order to fully characterize the uncertainty budget for reference dosimetry in MR‐guided radiation therapy systems. Purpose To identify and quantify key sources of uncertainty in the reference dosimetry of external high energy radiotherapy beams in the presence of a strong magnetic field. Methods In the absence of a formalized Task Group report for reference dosimetry in MR‐integrated linacs, the currently suggested formalism follows the TG‐51 protocol with the addition of a quality conversion factor k BQ accounting for the effects of the magnetic field on ionization chamber response. In this work, we quantify various sources of uncertainty that impact each of the parameters in the formalism, and evaluate their overall contribution to the final dose. Measurements are done in a 1.5 T MR‐Linac (Unity, Elekta AB, Stockholm, Sweden) which integrates a 1.5 T Philips MR scanner and a 7 MVFFF linac. The responses of several reference‐class small volume ionization chambers (Exradin:A1SL, IBA:CC13, PTW:Semiflex‐3D) and Farmer type ionization chambers (Exradin:A19, IBA:FC65‐G) were evaluated throughout this process. Long‐term reproducibility and stability of beam quality, , was also measured with an in‐house built phantom. Results Relative to the conventional external high energy linacs, the uncertainty on overall reference dose in MR‐linac is more significantly affected by the chamber setup: A translational displacement along y ‐axis of ± 3 mm results in dose variation of < |0.20| ± 0.02% (k = 1), while rotation of ± 5° in horizontal and vertical parallel planes relative to relative to the direction of magnetic field, did not exceed variation of < |0.44| ± 0.02% for all 5 ionization chambers. We measured a larger dose variation for xy ‐plane (horizontal) rotations (< |0.44| ± 0.02% (k = 1)) than for yz ‐plane (vertical) rotations (< ||0.28| ± 0.02% (k = 1)), which we associate with the gradient of k B,Q as a function of chamber orientation with respect to direction of the B 0 ‐field. Uncertainty in P ion (for two depths), P pol (with various sub‐studies including effects of cable length, cable looping in the MRgRT bore, connector type in magnetic environment), and P rp were determined. Combined conversion factor k Q × k B,Q was provided for two reference depths at four cardinal angle orientations. Over a two‐year period, beam quality was quite stable with being 0.669 ± 0.01%. The actual magnitude of was measured using identical equipment and compared between two different Elekta Unity MR‐Linacs with results agreeing to within 0.21%. Conclusion In this work, the uncertainty of a number of parameters influencing reference dosimetry was quantified. The results of this work can be used to identify best practice guidelines for reference dosimetry in the presence of magnetic fields, and to evaluate an uncertainty budget for future reference dosimetry protocols for MR‐linac.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».