Quantifying uncertainties associated with reference dosimetry in an MR‐Linac

2023· article· en· W4381848017 sur OpenAlexaff
Viktor Iakovenko, Brian Keller, Victor Malkov, Arjun Sahgal, Arman Sarfehnia

Notice bibliographique

RevueJournal of Applied Clinical Medical Physics · 2023
Typearticle
Langueen
DomainePhysics and Astronomy
ThématiqueAdvanced Radiotherapy Techniques
Établissements canadiensHealth Sciences CentreUniversity of TorontoSunnybrook Health Science Centre
Organismes subventionnairesnon disponible
Mots-clésDosimetryIonization chamberPhysicsLinear particle acceleratorMedical physicsRadiation therapyFormalism (music)Nuclear medicineComputer scienceIonizationMedicineOpticsRadiologyIonBeam (structure)

Résumé

récupéré en direct d'OpenAlex

Abstract Background Magnetic resonance (MR)‐guided radiation therapy provides capabilities to utilize high‐resolution and real‐time MR imaging before and during treatment, which is critical for adaptive radiotherapy. This emerging modality has been promptly adopted in the clinic settings in advance of adaptations to reference dosimetry formalism that are needed to account for the presence of strong magnetic fields. In particular, the influence of magnetic field on the uncertainty of parameters in the reference dosimetry equation needs to be determined in order to fully characterize the uncertainty budget for reference dosimetry in MR‐guided radiation therapy systems. Purpose To identify and quantify key sources of uncertainty in the reference dosimetry of external high energy radiotherapy beams in the presence of a strong magnetic field. Methods In the absence of a formalized Task Group report for reference dosimetry in MR‐integrated linacs, the currently suggested formalism follows the TG‐51 protocol with the addition of a quality conversion factor k BQ accounting for the effects of the magnetic field on ionization chamber response. In this work, we quantify various sources of uncertainty that impact each of the parameters in the formalism, and evaluate their overall contribution to the final dose. Measurements are done in a 1.5 T MR‐Linac (Unity, Elekta AB, Stockholm, Sweden) which integrates a 1.5 T Philips MR scanner and a 7 MVFFF linac. The responses of several reference‐class small volume ionization chambers (Exradin:A1SL, IBA:CC13, PTW:Semiflex‐3D) and Farmer type ionization chambers (Exradin:A19, IBA:FC65‐G) were evaluated throughout this process. Long‐term reproducibility and stability of beam quality, , was also measured with an in‐house built phantom. Results Relative to the conventional external high energy linacs, the uncertainty on overall reference dose in MR‐linac is more significantly affected by the chamber setup: A translational displacement along y ‐axis of ± 3 mm results in dose variation of < |0.20| ± 0.02% (k = 1), while rotation of ± 5° in horizontal and vertical parallel planes relative to relative to the direction of magnetic field, did not exceed variation of < |0.44| ± 0.02% for all 5 ionization chambers. We measured a larger dose variation for xy ‐plane (horizontal) rotations (< |0.44| ± 0.02% (k = 1)) than for yz ‐plane (vertical) rotations (< ||0.28| ± 0.02% (k = 1)), which we associate with the gradient of k B,Q as a function of chamber orientation with respect to direction of the B 0 ‐field. Uncertainty in P ion (for two depths), P pol (with various sub‐studies including effects of cable length, cable looping in the MRgRT bore, connector type in magnetic environment), and P rp were determined. Combined conversion factor k Q × k B,Q was provided for two reference depths at four cardinal angle orientations. Over a two‐year period, beam quality was quite stable with being 0.669 ± 0.01%. The actual magnitude of was measured using identical equipment and compared between two different Elekta Unity MR‐Linacs with results agreeing to within 0.21%. Conclusion In this work, the uncertainty of a number of parameters influencing reference dosimetry was quantified. The results of this work can be used to identify best practice guidelines for reference dosimetry in the presence of magnetic fields, and to evaluate an uncertainty budget for future reference dosimetry protocols for MR‐linac.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,002
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,508
Score d'incertitude au seuil0,637

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0020,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0010,000
Bibliométrie0,0000,001
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,001
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,085
Tête enseignante GPT0,413
Écart entre enseignants0,328 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations8
Publié2023
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueJournal of Applied Clinical Medical PhysicsMême sujetAdvanced Radiotherapy TechniquesTravaux en français237 207