Digital Platform for Continuous Monitoring of Patients Using a Smartwatch: Longitudinal Prospective Cohort Study
Notice bibliographique
Résumé
BACKGROUND: Since the COVID-19 pandemic, there has been a boost in the digital transformation of the human society, where wearable devices such as a smartwatch can already measure vital signs in a continuous and naturalistic way; however, the security and privacy of personal data is a challenge to expanding the use of these data by health professionals in clinical follow-up for decision-making. Similar to the European General Data Protection Regulation, in Brazil, the Lei Geral de Proteção de Dados established rules and guidelines for the processing of personal data, including those used for patient care, such as those captured by smartwatches. Thus, in any telemonitoring scenario, there is a need to comply with rules and regulations, making this issue a challenge to overcome. OBJECTIVE: This study aimed to build a digital solution model for capturing data from wearable devices and making them available in a safe and agile manner for clinical and research use, following current laws. METHODS: A functional model was built following the Brazilian Lei Geral de Proteção de Dados (2018), where data captured by smartwatches can be transmitted anonymously over the Internet of Things and be identified later within the hospital. A total of 80 volunteers were selected for a 24-week follow-up clinical trial divided into 2 groups, one group with a previous diagnosis of COVID-19 and a control group without a previous diagnosis of COVID-19, to measure the synchronization rate of the platform with the devices and the accuracy and precision of the smartwatch in out-of-hospital conditions to simulate remote monitoring at home. RESULTS: In a 35-week clinical trial, >11.2 million records were collected with no system downtime; 66% of continuous beats per minute were synchronized within 24 hours (79% within 2 days and 91% within a week). In the limit of agreement analysis, the mean differences in oxygen saturation, diastolic blood pressure, systolic blood pressure, and heart rate were -1.280% (SD 5.679%), -1.399 (SD 19.112) mm Hg, -1.536 (SD 24.244) mm Hg, and 0.566 (SD 3.114) beats per minute, respectively. Furthermore, there was no difference in the 2 study groups in terms of data analysis (neither using the smartwatch nor the gold-standard devices), but it is worth mentioning that all volunteers in the COVID-19 group were already cured of the infection and were highly functional in their daily work life. CONCLUSIONS: On the basis of the results obtained, considering the validation conditions of accuracy and precision and simulating an extrahospital use environment, the functional model built in this study is capable of capturing data from the smartwatch and anonymously providing it to health care services, where they can be treated according to the legislation and be used to support clinical decisions during remote monitoring.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,003 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,001 |
| Méta-épidémiologie (sens large) | 0,001 | 0,001 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,001 | 0,000 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,000 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,002 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,003 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».