Investigation of Internal Flow near Return Guide Vane Using Jet and Suction Flow
Notice bibliographique
Résumé
The Performance and efficiency of multistage centrifugal compressors, which are required to operate continuously over a long time, are expected to further improve in the future.Many studies have been conducted to optimize the design of various components of compressors such as impellers and diffusers.Recently, experimental and numerical studies were conducted on the energy loss reduction through internal flow treatment in return systems that divert flow to the next stage of pressure increase.Rube et al. reported that 5-10% reduction in the entire stage efficiency is due to flow losses in the return system [1].Rossbach et al. revealed that the secondary flow that is generated in the vaned passage by the strong inward swirl at high flow rates induces large-scale flow separation and the high mixing losses at the exit of the return guide vanes [2].In addition, Traficante et al. attempted the active flow control of an axial compressor-stator cascade using plasma actuators, continuous and synthetic jets, and found that the internal flow could be improved [3].However, the obtained results are limited and insufficient to determine the optimum feeding position and flow rate of these jets.Therefore, in this study, systematic investigations of the effects of jet and suction flow feed position and feeding flow rate on the improvement of the internal flow was conducted both experimentally and numerically.Specifically, computational fluid dynamics (CFD) utilizing Reynolds-averaged Navier-Stokes (RANS) equation with k-ωSST turbulence model was conducted, which was validated by comparing the static pressure on the suction surface obtained experimentally and by CFD.We discuss the relationship between the internal flow fields and the energy loss flowing over the vaned passage obtained from the numeric distributions such as the total and static pressure and residual angular momentum.The obtained CFD results show that the optimum slot-installation position and feeding flow rate differ for jet and suction flow, respectively.Furthermore, the flow separation region in the vaned passage is reduced by suppressing the development of the secondary flow.These results indicate that the proposed return guide vane using jet and suction flow reduces the total energy loss by improving the internal flow between the return vanes.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».