Role of Vertical Structures on Heat Exchange within Acoustic Standing Waves
Notice bibliographique
Résumé
Thermoacoustic cooling was proposed in the 1980's as an alternative environmentally friendly technology. Based on a gas cycle, the concept involved the immersion of a porous substrate and heat exchangers within a pressurized vessel. High amplitude acoustic standing waves supplied by an electrodynamically driven linear actuator, was used as the power source. Despite promising theoretical performance predictions, heavily based on broadly distributed software, no working prototype has ever demonstrated efficiencies that are competitive with that of conventional or other alternative technologies. The purpose of the study reported here was to quantify the cooling performance of cylindrical tubes and simplified heat exchanges in acoustic standing wave. The role of convected vortical structures, forming "hot spots," on the actual heat exchanger performance was elucidated through the use of combined particle image velocimetry (PIV) and particle laser induced fluorescence (PLIF) data. It was found that convected vortical structures tend to significantly degrade heat exchanger performance relative to predictions from linear acoustic models based on irrotational flow solutions. Computational studies of streaming flows within large amplitude standing waves were performed to illustrate their influence of the thermal performance of thermoacoustic devices. The results prompt the reconsideration of performance limits to include these factors in future thermoacoustic cooling system design.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».