A Novel Battery Thermal Management System based on Capillary Driven Evaporative Cooling
Notice bibliographique
Résumé
In this paper we present an experimental and a numerical study on a novel battery thermal management system (BTMS) based on capillary driven evaporative cooling (CDEC).The experimental study was conducted using Cu foam and Novec 7000 to determine the cooling performance of this system when cooled through a single surface of the battery at three different heating inputs: 10W, 20W and 30W.The system was further expanded to incorporate cooling from the two larger surfaces of the battery using a numerical model.Results from the experimental study showed that the maximum temperature of battery can be maintained below 50℃ for a heat input of 30W, when the cell is cooled using a single surface.This was further reduced to 40℃ when cooled from both surfaces.Furthermore, these temperatures were achieved through partial wetting of the battery surface due to a capillary rise of about 11% of the total battery height.This clearly demonstrates the superior cooling capabilities of this novel BTMS.However, the maximum temperature different recorded in the battery at a heat input of 30W was 5.47℃ which was a result of the uneven cooling rates in the wetted and nonwetted regions of the battery due to partial capillary rise.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».