Automated Large Vessel Occlusion Detection Software and Thrombectomy Treatment Times
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
Importance: The benefit of endovascular stroke therapy (EVT) in large vessel occlusion (LVO) ischemic stroke is highly time dependent. Process improvements to accelerate in-hospital workflows are critical. Objective: To determine whether automated computed tomography (CT) angiogram interpretation coupled with secure group messaging can improve in-hospital EVT workflows. Design, Setting, and Participants: This cluster randomized stepped-wedge clinical trial took place from January 1, 2021, through February 27, 2022, at 4 comprehensive stroke centers (CSCs) in the greater Houston, Texas, area. All 443 participants with LVO stroke who presented through the emergency department were treated with EVT at the 4 CSCs. Exclusion criteria included patients presenting as transfers from an outside hospital (n = 158), in-hospital stroke (n = 39), and patients treated with EVT through randomization in a large core clinical trial (n = 3). Intervention: Artificial intelligence (AI)-enabled automated LVO detection from CT angiogram coupled with secure messaging was activated at the 4 CSCs in a random-stepped fashion. Once activated, clinicians and radiologists received real-time alerts to their mobile phones notifying them of possible LVO within minutes of CT imaging completion. Main Outcomes and Measures: Primary outcome was the effect of AI-enabled LVO detection on door-to-groin (DTG) time and was measured using a mixed-effects linear regression model, which included a random effect for cluster (CSC) and a fixed effect for exposure status (pre-AI vs post-AI). Secondary outcomes included time from hospital arrival to intravenous tissue plasminogen activator (IV tPA) bolus in eligible patients, time from initiation of CT scan to start of EVT, and hospital length of stay. In exploratory analysis, the study team evaluated the impact of AI implementation on 90-day modified Rankin Scale disability outcomes. Results: Among 243 patients who met inclusion criteria, 140 were treated during the unexposed period and 103 during the exposed period. Median age for the complete cohort was 70 (IQR, 58-79) years and 122 were female (50%). Median National Institutes of Health Stroke Scale score at presentation was 17 (IQR, 11-22) and the median DTG preexposure was 100 (IQR, 81-116) minutes. In mixed-effects linear regression, implementation of the AI algorithm was associated with a reduction in DTG time by 11.2 minutes (95% CI, -18.22 to -4.2). Time from CT scan initiation to EVT start fell by 9.8 minutes (95% CI, -16.9 to -2.6). There were no differences in IV tPA treatment times nor hospital length of stay. In multivariable logistic regression adjusted for age, National Institutes of Health Stroke scale score, and the Alberta Stroke Program Early CT Score, there was no difference in likelihood of functional independence (modified Rankin Scale score, 0-2; odds ratio, 1.3; 95% CI, 0.42-4.0). Conclusions and Relevance: Automated LVO detection coupled with secure mobile phone application-based communication improved in-hospital acute ischemic stroke workflows. Software implementation was associated with clinically meaningful reductions in EVT treatment times. Trial Registration: ClinicalTrials.gov Identifier: NCT05838456.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle