A Study of V(IV/V) and V(II/III) Reactions on Carbon Based Electrodes

2023· article· en· W4386866775 sur OpenAlexaff
Chaojie Song, Roberto Neagu, Khalid Fatih

Notice bibliographique

RevueECS Meeting Abstracts · 2023
Typearticle
Langueen
DomaineEngineering
ThématiqueAdvanced battery technologies research
Établissements canadiensNational Research Council Canada
Organismes subventionnairesnon disponible
Mots-clésRedoxVanadiumGraphiteCyclic voltammetryCarbon fibersMaterials scienceGlassy carbonInorganic chemistryElectrodePyrolytic carbonElectrochemistryElectrochemical kineticsChemistryVoltammetryPhysical chemistryOrganic chemistryComposite materialPyrolysis

Résumé

récupéré en direct d'OpenAlex

The vanadium redox flow battery (VRFB) is one of the most promising energy storage technologies for large scale commercialization. Carbon based electrodes, such as carbon felts or carbon paper, are used for V(II/III) and V(IV/V) reactions. To improve the vanadium redox reaction kinetics, the carbon electrodes are usually activated by a variety of methods such as thermal treatment, heteroatom doping, catalyst incorporation etc. [1] It is generally considered that surface functional group such as C–OH, C=O play an important role in vanadium redox reaction [1-6]. Even though there are reports showing higher surface functional group content e.g. total C–O content leads to improved vanadium redox reaction kinetics [2-6], qualitative correlation of the surface property of the carbon materials and the vanadium redox reaction is not reported. There is a need for fundamental understanding of the surface properties of the carbon electrodes and their relation with the reaction kinetics, including the key parameters that determine them. In this work, using cyclic voltammetry (CV), we studied the surface properties of a variety of carbon based electrodes (glassy carbon (GC), edge plane pyrolytic graphite, base plane pyrolitic graphite, graphite (from Pine Research, called graphite-Pine thereafter), graphite rod, and H 2 SO 4 soaked graphite rod), and the V(II/III) and V(IV/V) reaction kinetics on these electrodes. The goal of soaking the graphite rod electrode in H 2 SO 4 is to activate the electrode and make it comparable to the carbon felt electrode [1]. XPS was also used to analyze the functional group. The relationship between the surface properties and the reaction kinetic parameters was analyzed. Fig. 1 compares the cyclic voltammograms (CV) of the edge plane, basal plane graphite and GC electrodes in 2 M H 2 SO 4 . Two redox couples are observed, ascribed to C=O and COOH group redox peak respectively [7]. On basal plane electrode, these two redox peaks are less significant, and an extra reduction peak is observed at 0.24 V due to the C–OH reduction. On the GC electrode, the C=O redox peak is still discernable but the COOH redox peak is almost undetectable. A capacitance region appears between 0.6 – 0.75 V vs Ag/AgCl for all these electrodes. Similar features are observed with the graphite-Pine, graphite rod and H 2 SO 4 soaked graphite rod electrodes with significantly enhanced redox peaks and larger capacitance. The H 2 SO 4 soaked graphite rod electrode presents the highest surface functional group density and capacitance. XPS also shows that the H 2 SO 4 soaked graphite rod electrode has the highest total C–O content. CV of V(IV/V) and V(II/III) were measured using these electrodes at different scan rates. Fig. 2 shows the CV of V(IV/V) reaction on these electrodes. The three graphite rod electrodes show better reversible feature than the edge plane, basal plane and GC electrodes. Diffusion coefficient, transfer coefficient and reaction rate constant were obtained from the CVs. The diffusion coefficient follows the sequence of soaked graphite rod > graphite rod > Graphite-Pine > Edge plane > GC > basal plane electrode. The transfer coefficient and reaction rate constant are also different for these electrodes. Similarly, the diffusion coefficient, transfer coefficient and reaction rate constant are obtained for the V(II/III) reaction. The diffusion coefficient and reaction rate constant for the V(II/III) reaction are smaller than that for the V(IV/V) reaction on the corresponding electrodes. For both V(IV/V) and V(II/III), a linear relationship was found for diffusion coefficient versus the logarithm of capacitance and C=O group functional group. Higher value of log(capacitance) and log(C=O density) leads to larger diffusion coefficient. However, there is no clear relationship between transfer coefficient, reaction rate constant vs capacitance or C=O density. It seems that the capacitance and C=O functional group density are the importance parameters determining the vanadium redox reaction kinetics. References He, Y. Lv, T. Zhang, Y. Zhu, L. Dai, S. Yao., W. Zhu, L. Wang, Chem. Eng. J., 427 (2022) 131680 Zhang, J. Xia, Z. Li, H. Zhou, L. Liu, Z. Wu, X. Qiu, Electrochim. Acta 89 (2013) 429– 435 Liu, L. Yang, Q. Xu, C. Yan, RSC Adv., 2014, 4, 55666 Choi, H. Noh, S. Kim, R. Kim, R. Kim, J. Lee, J. Heo, H.-T. Kim, J. Energy Storage, 21 (2019) 321 – 327 Eifert, R. Banerjee, Z. Jusys, R. Zeis, J. Electrochem. Soc., 165 (2018) A2577 – A2586 Leuna, D. Priyadarshani, A. K. Tripathi, M. Neergat, J. Electroanal. Chem., 878 (2020) 114590 K. Singh, M. Pahlevaninezhad, N. Yasri, E. P. L. Roberts, ChemSusChem 2021, 14, 2100–2111 Figure 1

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Expérimental (laboratoire) · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,593
Score d'incertitude au seuil0,520

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,025
Tête enseignante GPT0,282
Écart entre enseignants0,257 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeExpérimental (laboratoire)
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2023
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueECS Meeting AbstractsMême sujetAdvanced battery technologies researchTravaux en français237 207