MétaCan
Menu
Retour à la cohorte
Enregistrement W4387099612 · doi:10.1016/s2589-7500(23)00130-9

Comparison of humans versus mobile phone-powered artificial intelligence for the diagnosis and management of pigmented skin cancer in secondary care: a multicentre, prospective, diagnostic, clinical trial

2023· article· en· W4387099612 sur OpenAlex

Pourquoi ce travail est dans la base

Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.

affAu moins un auteur déclare une institution canadienne dans l'instantané OpenAlex épinglé.

Notice bibliographique

RevueThe Lancet Digital Health · 2023
Typearticle
Langueen
DomaineMedicine
ThématiqueCutaneous Melanoma Detection and Management
Établissements canadiensMetaOptima Technology (Canada)
Organismes subventionnairesnon disponible
Mots-clésMedicineTeledermatologyClinical trialReferralSkin cancerGold standard (test)Prospective cohort studyPhysical examinationSurgeryCancerRadiologyPathologyTelemedicineHealth careFamily medicineInternal medicine

Résumé

récupéré en direct d'OpenAlex

BACKGROUND: Diagnosis of skin cancer requires medical expertise, which is scarce. Mobile phone-powered artificial intelligence (AI) could aid diagnosis, but it is unclear how this technology performs in a clinical scenario. Our primary aim was to test in the clinic whether there was equivalence between AI algorithms and clinicians for the diagnosis and management of pigmented skin lesions. METHODS: In this multicentre, prospective, diagnostic, clinical trial, we included specialist and novice clinicians and patients from two tertiary referral centres in Australia and Austria. Specialists had a specialist medical qualification related to diagnosing and managing pigmented skin lesions, whereas novices were dermatology junior doctors or registrars in trainee positions who had experience in examining and managing these lesions. Eligible patients were aged 18-99 years and had a modified Fitzpatrick I-III skin type; those in the diagnostic trial were undergoing routine excision or biopsy of one or more suspicious pigmented skin lesions bigger than 3 mm in the longest diameter, and those in the management trial had baseline total-body photographs taken within 1-4 years. We used two mobile phone-powered AI instruments incorporating a simple optical attachment: a new 7-class AI algorithm and the International Skin Imaging Collaboration (ISIC) AI algorithm, which was previously tested in a large online reader study. The reference standard for excised lesions in the diagnostic trial was histopathological examination; in the management trial, the reference standard was a descending hierarchy based on histopathological examination, comparison of baseline total-body photographs, digital monitoring, and telediagnosis. The main outcome of this study was to compare the accuracy of expert and novice diagnostic and management decisions with the two AI instruments. Possible decisions in the management trial were dismissal, biopsy, or 3-month monitoring. Decisions to monitor were considered equivalent to dismissal (scenario A) or biopsy of malignant lesions (scenario B). The trial was registered at the Australian New Zealand Clinical Trials Registry ACTRN12620000695909 (Universal trial number U1111-1251-8995). FINDINGS: The diagnostic study included 172 suspicious pigmented lesions (84 malignant) from 124 patients and the management study included 5696 pigmented lesions (18 malignant) from the whole body of 66 high-risk patients. The diagnoses of the 7-class AI algorithm were equivalent to the specialists' diagnoses (absolute accuracy difference 1·2% [95% CI -6·9 to 9·2]) and significantly superior to the novices' ones (21·5% [13·1 to 30·0]). The diagnoses of the ISIC AI algorithm were significantly inferior to the specialists' diagnoses (-11·6% [-20·3 to -3·0]) but significantly superior to the novices' ones (8·7% [-0·5 to 18·0]). The best 7-class management AI was significantly inferior to specialists' management (absolute accuracy difference in correct management decision -0·5% [95% CI -0·7 to -0·2] in scenario A and -0·4% [-0·8 to -0·05] in scenario B). Compared with the novices' management, the 7-class management AI was significantly inferior (-0·4% [-0·6 to -0·2]) in scenario A but significantly superior (0·4% [0·0 to 0·9]) in scenario B. INTERPRETATION: The mobile phone-powered AI technology is simple, practical, and accurate for the diagnosis of suspicious pigmented skin cancer in patients presenting to a specialist setting, although its usage for management decisions requires more careful execution. An AI algorithm that was superior in experimental studies was significantly inferior to specialists in a real-world scenario, suggesting that caution is needed when extrapolating results of experimental studies to clinical practice. FUNDING: MetaOptima Technology.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Autre devis · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,912
Score d'incertitude au seuil0,321

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0010,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,144
Tête enseignante GPT0,455
Écart entre enseignants0,311 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle