STATEMENT OF PROBLEM: Three-dimensional (3D) printed casts are a suitable alternative to dental stone casts. Contemporary dental design computer programs permit designing definitive casts with removable dies with different root geometries and retention mechanisms. Studies on the positional trueness of 3D printed removable dies with different root geometries are lacking. PURPOSE: The purpose of this in vitro study was to investigate the 3D displacements of three 3D printed removable die designs with different root geometries. MATERIAL AND METHODS: The digital file of a dental stone alveolar cast with root-form removable dies (MOD UJ IV Fixed Prosthetics; Ivoclar AG) was used as a reference to create 3 removable die and alveolar cast designs (Root Form, RF; Conical, CON; Cylindric, CYL) with different root geometries in 2 dental design computer programs (DentalCAD 3.1 Rijeka; exocad; GmbH; InLab CAD 22.0; Dentsply Sirona). 3 equidistant Ø1-mm spheres (C, Cervical; M, Middle; O, Occlusal) were designed on the buccal surface of the coronal portion of the removable die to evaluate their displacement. A total of 45 alveolar casts with 45 removable dies were fabricated using a stereolithographic 3D printer (Form 3; Formlabs); each die group consisted of 15 specimens. After fabrication and postprocessing, the specimens were scanned, and their digital files were analyzed in a metrology-grade computer program to evaluate the displacement of the removable dies with respect to the position of the die in the master reference file. Subsequently, the data were analyzed using a 3-way analysis of variance (ANOVA) followed by step-down Bonferroni-corrected pairwise comparisons (α=.05). RESULTS: Two statistically significant 2-way interactions were detected between the independent variables, die design and direction (P<.001), and location and direction (P<.001). The post hoc analysis identified significant differences between the displacement values of RF and CYL (P<.001) and RF and the CON (P<.001) designs on the Y axis. The measured displacements were statistically different between the C and O locations on the Y axis (P=.001) and the M and O locations on the Z axis (P=.006). CONCLUSIONS: The root geometry of a 3D printed removable die and alveolar cast can affect seating, and variable degrees of tipping of the removable die can be seen. The seating and congruence of the removable die with the interocclusal space and relationships observed intraorally should be confirmed before adjusting indirect restorations.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».