Optimization of the Thermal Performance of a CO2 Geothermal Thermosyphon
Notice bibliographique
Résumé
Summary This paper showcases the utilization of response surface methodology (RSM) to optimize the performance of a CO2 geothermal thermosyphon. The design parameters include the filling ratio, the flow rate of the cooling fluid and the difference between the ground and the cooling fluid inlet temperatures, while the response parameters are the heat transfer rate (Q) and effectiveness (εff). Using the RSM, two models were developed to establish correlations between input parameters and corresponding response. Overall, it is concluded from the RSM that the flow rate and the temperature difference between the ground and the heat transfer fluid inlet temperatures are the factors that have the greatest impact on Q and εff, while the filling ratio has only a slight effect on Q and no effect on εff. The maximum heat transfer rate and effectiveness achieved are 1.86 kW and 47.8%, respectively. Moreover, these optimal values are associated with different flow rate levels, indicating distinct operating regions for maximizing Q and εff within the GT system. Therefore, a multi-response optimization approach is essential to simultaneously optimize both Q and εff.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».