Comprehensive Kinematic Model of a Tendon-Driven Wearable Tremor Suppression Device
Notice bibliographique
Résumé
Wearable devices can suppress or reduce hand tremor motion associated with neurological disorders such as Parkinson's disease. Tendon-driven transmission systems have been proposed as a way to decrease the size and weight of these devices; however, they have complex control system requirements due to their substantially nonlinear behavior. To address this issue, this study focused on the development of a comprehensive kinematic model of a wearable tremor suppression glove that more accurately calculates the tendon displacement during hand motion. The novelty lies in the identification of the threshold bending angle for each joint at which the driven tendon touches the arc of the joint. The derived kinematic model of the glove was verified by both simulation and benchtop experiments, and the proposed model was validated during single-joint and multijoint hand movements. The kinematic model shows a mean 2-D correlation coefficient of 0.96 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\boldsymbol{\pm }$</tex-math></inline-formula> 0.01 with the experimental data. Compared to the Euclidean norm model presented in the literature, it presents an average 83% improvement (a 4%–96% reduction in root mean square errors depending on the joint), which is most significant for increasing tendon displacements.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».