Design and Demonstration of a Microelectromechanical System Single-Ring Resonator with Inner Ring-Shaped Spring Supports for Inertial Sensors
Notice bibliographique
Résumé
This paper presents a novel single-ring resonator design and experimentally demonstrates its dynamic behavior. The proposed ring resonator design is simple and has a solid anchor at its center connected to an outside ring via inner ring-shaped springs. The mode shapes and frequency of the ring resonator were determined numerically and compared with analytical approaches, and the minimum split frequency was observed for the n = 3 mode of vibration. Numerical and analytical methods were used to determine the resonance frequencies, pull-in voltage, resonance frequency shift and harmonic response of the ring resonator for different silicon orientations. The split frequency in the n = 3 mode of vibration increases by the applied DC bias voltage almost by the same amount for all types of silicon. When an AC voltage with a 180-degree phase is applied to two opposite electrodes, the ring has two resonance frequencies in mode n = 2, and when the AC voltage applied to two opposite electrodes is in the same phase, the ring has one resonance frequency regardless of the crystal orientation of silicon. Prototypes were fabricated using a double silicon-on-insulator-based wafer fabrication technique and were tested to verify the resonator performance.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».